MacKay Guardian™ Solo
Operation and Maintenance Guide, v. 1.5
7)
Spray a squirt of ProGold™ XPG5 conditioning treatment on the connectors and re-install
a coin discriminator into the mating header.
8)
Assemble the parts previously removed.
9)
Press the reset button and ensure that the meter is in service. Drop a coin 10 or more
times through the meter and observe for proper acceptance.
WARNING! SHARP METAL OBJECTS SHOULD NOT BE USED AT ANY TIME TO SERVICE OR
CLEAR COIN JAMS FROM THE COIN DISCRIMINATOR ASSEMBLY.
9.7
Removal of the Main Control Board (MCB) Assembly
1)
Disconnect and remove the main battery as previously described
2)
Disconnect the lower coin chute assembly as previously described
3)
Remove the two lower MCB retaining screws (see illustration)
4)
Remove the two upper MCB from mount screws (see illustration)
9.8
Removal of the wireless cellular expansion board (WCEB)
1)
Unplug the wireless cellular expansion board (WCEB) by gently lifting up on the board
until it pulls free of the two mating connectors on the MCB. If the WCEB or the antenna
cover is not being replaced, there is no need to disconnect the antenna coax cable
attached to it, and the WCEB can be swung out of the way and placed next to the meter
front cover with the antenna coax still attached. (See illustration).
50
Содержание Guardian SOLO
Страница 1: ...JJ12 001 v1 5 February 2013...
Страница 4: ......
Страница 10: ......
Страница 77: ...MacKay Guardian Solo Operation and Maintenance Guide v 1 5 Notes 67...
Страница 78: ...MacKay Guardian Solo Operation and Maintenance Guide v 1 5 Notes 68...
Страница 79: ...MacKay Guardian Solo Operation and Maintenance Guide v 1 5 69...