MacKay Guardian™ Solo
Operation and Maintenance Guide, v. 1.5
•
Figure 25 - Wireless Cellular Expansion Board
2)
Disconnect the two button flex cables by gently pressing down on the retaining latches
on the end of each flex cable, and then gently sliding the flex connectors out of the
mating connectors (J21, J22) on the MCB (see illustration).
•
Figure 26 - button flex cable connectors on MCB
3)
Disconnect the 3-pin solar panel harness from the MCB by pressing on the release tabs
of the coax connector and lifting it clear of the MCB.
•
Figure 27 - 3-Pin solar panel connector
4)
Gently lift the MCB clear of the main front cover zinc assembly.