5)
Remove any protective insulating tape around the end of the
new replacement battery pack connector. Apply a very small
amount of dielectric grease to the exposed metal contacts on
both exposed mating ends of the battery connectors (Dow
Corning 4 Electrical Insulating Compound).
•
Figure 23 – MacKay
Guardian™ Solo Lithium-Ion
Rechargeable Battery Pack
6)
Attach the new, previously tested, replacement battery pack by connecting the mating
battery connector to the MCB.
DO NOT CONNECT AND THEN IMMEDIATELY
DISCONNECT THE BATTERY PACK!
Wait until the meter lamp test has completed (if
replacing a dead battery) or at least 5 seconds before disconnecting a newly replaced
battery pack from the meter.
7)
Place the battery pack back into the meter battery compartment, ensuring that the wiring
harness is routed on the same side as the connector. The “INSTALLED DATE” label on
the battery pack should be facing outwards and the repairperson replacing the battery
should write the current date on the label using either a pencil or waterproof permanent
marker.