![background image](http://html.mh-extra.com/html/macdon/d1-series/d1-series_unloading-and-assembly-instructions_685658402.webp)
215184
378
Revision A
1003737
A
B
Figure 9.164: CLAAS Combine Display, Console, and
Control Handle
3.
Select FRONT ATTACHMENT PARAMETER SETTINGS
icon (A). A list of settings appears.
4.
Select SENSITIVITY CAC (B) from the list.
1009743
A
B
Figure 9.165: CLAAS Combine Display
5.
Select SENSITIVITY CAC icon (A).
NOTE:
To set the sensitivity, you will have to change CUTTING
HEIGHT ADJUSTMENT (B) from the 0 default. The settings
from 1
–
50 provide a faster response, whereas the settings
from -1 to -50 provide a slower response. For best results,
make adjustments in increments of 5.
6.
Increase the CUTTING HEIGHT ADJUSTMENT setting if the
reaction time between the header and the float module is
too slow while cutting on the ground, and decrease the
CUTTING HEIGHT ADJUSTMENT setting if the reaction time
between the header and the float module is too fast.
7.
Increase the sensitivity if the header is lowered too slowly,
and decrease the sensitivity if the header hits the ground
too hard or is lowered too quickly.