215184
325
Revision A
1018430
A
C
C
B
Figure 9.37: Automatic Controls and Sensitivity
Settings
1.
Automatic Control Functions:
There are toggle (OFF/ON)
switches on the HEADER SETTINGS page for the automatic
control functions. For MacDon headers, ensure the
following two functions are enabled as shown:
•
RTC (return to cut) (A)
•
AHHC (automatic header height control) (B)
All other switches are disabled (not highlighted).
2.
Sensitivity
setting (C) controls how responsive a control
(RTC or AHHC) is to a given change in sensor feedback. The
setting fields are located directly below the toggle switches.
To enter a new sensitivity setting, touch the setting field
below the specific toggle switch, and enter the new value in
the on-screen keyboard.
•
Increase sensitivity if the combine does not change the
feeder position quickly enough when in Auto Mode.
•
Decrease sensitivity if the combine hunts for a position
in Auto Mode.
NOTE:
Recommended sensitivity starting points for MacDon
headers are:
•
50
for RTC (A)
•
60
for AHHC (B)
1018432
A
Figure 9.38: Header Speed Control Settings
3.
Header Speed:
HEADER CONTROL SPEED area (A) on the
HEADER SETTINGS page is used to adjust the following
speeds:
•
Tilt left and right is the lateral tilt of the combine
faceplate
•
Header up and down (slow and fast speeds) is a two-
stage button with slow speed on the first detent and
fast on the second
NOTE:
Recommended header control speed starting points
•
Slow: Up 45/Down 40
•
Fast: Up 100/Down 100