215184
352
Revision A
1009753
A
Figure 9.105: Case IH Combine Display
5.
Locate the HEADER SUB TYPE field.
6.
Select 2000 (A).
1025378
A
B
C
D
E
F
Figure 9.106: Case IH Combine Display
7.
Select HEAD 2 tab (A).
8.
In HEADER SENSORS field (B), select ENABLE.
9.
In HEADER PRESSURE FLOAT field (C), select NO.
10. In HEIGHT/TILT RESPONSE field (D), select FAST.
11. In AUTO HEIGHT OVERRIDE field (E), select YES.
12. Press down arrow (F) to go to the next page.
1025380
A
B
Figure 9.107: Case IH Combine Display
13. Locate HHC HEIGHT SENSITIVITY field (A), and set as
follows:
•
If using a single-sensor system:
Set HHC HEIGHT
SENSITIVITY to 180.
•
If using a two-sensor system:
Set HHC HEIGHT
SENSITIVITY to 250.
NOTE:
If hunting occurs during operation, decrease this setting by
20 points at a time until hunting no longer occurs.
14. Set HHC TILT SENSITIVITY (B) to 150. Increase or decrease
as desired.