37.4.2 INITIAL SETTING MODE
NOTE
The bargraph lower and upper limits are disabled with “no bargraph” selected for the bargraph type parameter.
for ≥ 3 sec.
for ≥ 1 sec.
or
Measurement
started
Measurement
stopped
Initial Setting Mode
Measuring Mode
Input type
Pt 100 (JIS ’ 97, IEC), Pt 50 Ω (JIS ’ 81),
Pt 1000, JPt 100 (JIS ’ 89), Pt 100 (JIS ’ 89)
Temperature unit
°C, °F
0.00 (2 decimal places)
0.0 (1 decimal place)
0 (no decimal point)
Input comp. A input value
-999.99 – 9999.99
Input comp. A comp. value
-999.99 – 9999.99
Decimal point position
Bargraph type
INC (unidirectional bar)
INCR (unidirectional bar (reverse LCD))
DEV (bidirectional bar)
DEVR (bidirectional bar (reverse LCD))
OFF (no bargraph)
Bargraph lower limit
-999.99 – 9999.99
Selectable only with the DC output code ‘1’.
*
Bargraph upper limit
-999.99 – 9999.99
Analog output type
4-20MA, 0-5V, 5V,
10V, 0-20MA
Analog output
function mode
DISPLY, TEMP
Analog output 0%
-999.99 – 9999.99
Analog output 100%
-999.99 – 9999.99
Analog output 0%
adjustment
UP (increasing),
DOWN (decreasing)
Analog output 100%
adjustment
UP (increasing),
DOWN (decreasing)
Input comp. B input value
-999.99 – 9999.99
Input comp. B comp. value
-999.99 – 9999.99