220
47DR OPERATING MANUAL EM-9509-B Rev.7
37.2 MODEL NUMBERING
Code number:
47DR–1[1][2][3]–[4][5]
INPUT – FIELD-SELECTABLE
1: JPt 100 (JIS ’89), Pt 100 (JIS ’89),
Pt 100 (JIS ’97, IEC), Pt 50 Ω (JIS ’81), Pt 1000
[1] DC OUTPUT
0: Without
1: With
[2] EXCITATION SUPPLY
1: +12 V sensor excitation
2: +24 V two-wire transmitter excitation
[3] I/O OPTIONS
0: None
1: Alarm output: N.O. relay, 4 points
2: Alarm output: SPDT relay, 2 points
3: Alarm output: N.O. photo MOSFET relay, 4 points
4: Network interface: RS-485 / Modbus-RTU
5: BCD output
6: Event trigger input
7: Alarm output: N.O. relay, 4 Network inter-
face: RS-485 / Modbus-RTU
8: Alarm output: SPDT relay, 2 Network inter-
face: RS-485 / Modbus-RTU
9: Alarm output: N.O. photo MOSFET relay, 4
BCD output
A: Event trigger input + BCD output
[4] POWER INPUT
AC Power
M2: 100 – 240 V AC (operational voltage range
85 – 264 V, 50/60 Hz)
DC Power
R: 24 V DC (operational voltage range 24 V ±10%,
ripple 10% p-p max.)
P: 110 V DC (operational voltage range 85 – 150 V,
ripple 10% p-p max.)
[5] OPTIONS
Blank: None
/Q: With options (specify the specification)
■
SPECIFICATIONS OF OPTION: Q
COATING (For the detail, refer to M-System's web site.)
Moving parts and indicators are not coated.
/C01: Silicone coating
/C02: Polyurethane coating
/C03: Rubber coating
TERMINAL SCREW MATERIAL
/S01: Stainless steel
EX-FACTORY SETTING
/SET: Preset according to the Ordering Information Sheet (No. ESU-9509)