Setup Guide for the RadioRA Chronos System Bridge
76
Section 6 - CCI Programming
Contact Closure Programming
Setting up a General Purpose Contact Closure Input for
Time Clock Mode Control
Either CCI 1 or CCI 2 can be programmed to control the mode of the Time Clock (Home or Away). Follow the
procedure below to program a closure to control the Time Clock Mode.
Step 1
Go to Contact Closure Setup
Main Menu
Contact Closure Setup
From
Contact Closure Setup
, select either
CCI 1
or
CCI 2
.
Step 2
Setup Contact Closure Type
CCI 2 Setup
Set Type - - -
Closure Settings
Clock Mode
Back
Help
Test CCI
Use
and
to set the type to Clock Mode.
Note:
Only one CCI can be set to control the
mode of the Time Clock.
Step 3
Setup Closure Settings
From
CCI 1 (or CCI 2) Setup
, select
Closure
Settings
.
Use
and
to select whether a closure of
the CCI indicates Home or Away.
Press
“Done” (
button)
to accept the setting.
• The CCI is now set up for Time Clock
Mode Control.
Closure Settings
the home owner is
Cancel
Done
Away
When the CCI is closed,