Setup Guide for the RadioRA Chronos System Bridge
68
Section 5 - RS-232 Programming
Step 1
Go to Device Number Setup
Assigning Zone Numbers
Zone Numbers are only necessary if the Chronos
TM
System Bridge serial port will be used to directly control indi-
vidual zones or if RS-232 feedback is desired when a zone changes. Prior to assigning zone numbers, fill out the
Zone Number worksheets (for each system) found in the RadioRA
®
RS-232 Protocol and Programming Guide
(P/N 044-038).
RS-232 Port Programming
Main Menu
RS-232 Setup
Device Number Setup
Note:
If the
Chronos
System Bridge is bridging two
systems, device number setup must be done for each
system.
Device Number Setup
will appear as below:
Use
and
to highlight the system, and press
OK
to proceed to the next step.
Device Number Setup
System 1 Device Numbers
Back
Help
System 2 Device Numbers
Step 2
Select a Zone Number to
assign
From
Device Number Setup
, select
Assign Zone
Numbers
.
Use
and
to change the Zone Number to be
assigned.
Assign Zone Numbers
1
Help
Done
Zone is Unassigned
Zone Number - - - - - - - -
Step 3
Assign a Lighting Zone
Control to a Zone Number
Assign a Dimmer or Switch to the selected
Zone Number by turning the Dimmer or
Switch ON.
Assign a GRAFIK Eye
®
/GRAFIK RA
TM
Control
Unit to the selected Zone Number by chang-
ing the scene of the
GRAFIK Eye/GRAFIK RA
Control Unit.
Switch
OR
Dimmer
If the wrong Lighting Zone Control is assigned
to a Zone Number, simply assign the correct
Lighting Zone Control to the Zone Number.