Setup Guide for the RadioRA Chronos System Bridge
70
Section 5 - RS-232 Programming
Assigning Master Control Numbers
Master Control Numbers are only necessary if:
· The Chronos
TM
System Bridge RS-232 port will be used to control the LEDs on a Master Control
· RS-232 Feedback is desired when a Master Control button is pressed
· RS-232 Feedback is desired when a Cordless Master Control wakes up or goes to sleep
Prior to assigning Master Control numbers, fill out the Master Control Number worksheets (for each system)
found in the RadioRA
®
RS-232 Protocol and Programming Guide (P/N 044-038).
RS-232 Port Programming
Step 1
Go to Device Number Setup
Main Menu
RS-232 Setup
Device Number Setup
Note:
If the
Chronos
System Bridge is bridging two
systems, device number setup must be done for each
system.
Device Number Setup
will appear as below:
Use
and
to highlight the system, and press
OK
to proceed to the next step.
Device Number Setup
System 1 Device Numbers
Back
Help
System 2 Device Numbers
Step 2
Select a Master Control
Number to assign
From
Device Number Setup
, select
Assign Control
Numbers
.
Use
and
to change the Control Number to be
assigned.
Assign Control Numbers
1
Help
Done
Control is Unassigned
Control Number - - - - - -
ALL ON
ALL OFF
Tabletop Master
Wall Master
OR
Step 3
Assign a Master Control to a
Control Number
Assign a Master Control to the selected
Control Number by pressing the ALL ON but-
ton. For Master Controls with Raise/Lower
buttons, press any
programmed
button.
Assign a Switch Closure Interface to a Control
Number by activating any previously
pro-
grammed
input channel (1-5) on the Switch
Closure Interface. An input channel can be
activated by an external device or by jumper-
ing a wire between the input channel and
Common.
Switch Closure Interface