![Lupus Electronics LUPUSEC-XT1 Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/lupus-electronics/lupusec-xt1/lupusec-xt1_manual_1950353087.webp)
87
Installation:
There are five holes in the middle of the motion detector’s
back (3 slots, 2 small holes) to fasten the corner mount. Next
to them, four notches are located for frontal wall mounting.
There are two additional notches at each side to mount the
motion detector angularly to the wall. You need to screw the
screws through the notches for the wall mounting.
Warm-up phase:
The PIR motion detector is set to a one-minute warm-up phase every time the
system is armed or set to home mode. During that phase, it cannot detect any
motions. Do not trigger any motions, as otherwise the warm-up phase extends by
another minute.
Note:
The horizontal angle of the PIR motion detector is 130°.
To enable the optimal motion detection, install the motion detector at a height of
1.8 to 2.0
meters and align the Test button to the top.
Pay attention to the dead spot directly below the detector.
Do not install the motion detector within the detection range of another detector
(e.g. motion detector with light in front of the entrance door).
Do not expose the motion detector to direct sunlight.
Do not install the motion detector close to heaters or air conditioning systems.
The detection range is approx. 12 meters, if the detector is installed at a height of
2 meters. At a height of e.g. 1.9 meters, the detector is pet immune up to approx.
7 meters.
Set the jumper 3 (JP3) to OFF to reduce the sensitivity.
Set the jumper 2 (JP2) to OFF to activate the battery check (supervisor).
Unless in the test mode, the motion detector can detect a motion only every
three
minutes (irrespective of the control unit status).