Mounting bracket
6.
Attachment hook
Put the smoke detector into operation
1.
After you inserted the batteries, two brief signals sound. The LED starts flashing.
You have six minutes (warm-up phase) to add the smoke detector to the control
unit.
2.
Open the configuration page of the control unit and start the login process in the
Sensors menu.
3.
Press the Test button at the smoke detector. Two brief signal tones sound.
4.
If the control unit detects the device, it emits a signal tone for confirmation.
5.
Now add the smoke detector to the control unit.
Note:
The calibration starts after the six minutes warm-up phase of the smoke detector.
A short beep sounds every 100 seconds during these six minutes. The calibration
takes about 2 to 16 minutes and is completed at the end with two successful
signals. If the calibration failed after 16 minutes, a constant beep will sound. In
that case, remove the batteries and restart with step 1.
You cannot integrate the smoke detector during the calibration; this is possible
only before or after the calibration process.
6.
Perform an optional range test.
For this purpose, open the menu
Sensors
Range
and click on Start. Take the
smoke detector to the place of installation and press the Test button of the smoke
detector. The test menu of the control unit indicates the signal strength of the
radio transmission. The higher the value the better the radio signal (1-9).
Mounting of smoke detector:
1.
Use the bracket (5) as a template to drill the holes.
2.
Mount the bracket so that the two hooks (6) face down.
3.
Press the installation notches (4) onto the attachment hooks (6)
and lock it with pressure and a clockwise turn, making sure that
the line located at the side of the smoke detector is directly below
one of the hooks.
In case of alarm:
If the smoke concentration exceeds the threshold, the detector will immediately
report this to the XT1 and additionally emit a loud signal tone for ten seconds. If the
smoke concentration measured after these ten seconds is still high, a signal tone is
emitted again for ten seconds, until there is no more smoke in the measuring
chamber. If you press the Test button in case of an alarm, the smoke detector will be
deactivated for ten minutes. After these ten minutes, the smoke detector will sound
two signal tones and return to its normal operating mode
.
Place of installation of smoke detector:
Install the smoke detector always at the highest point and with minimum distance