120
Cable connection diagram:
Range test:
1.
Open the control unit menu
Sensors
Range and press Start.
2.
Press the Test button of the in-wall relay.
3.
The sensor and the signal strength should be indicated.
External switch:
You can use an external switch for easier handling.
The operation of the external switch is similar to the direct operation of the Test
button (activates or deactivates the relay).
Note:
The relay can be activated and deactivated manually on the website.
You can save dynamic or scheduled programming in the Automation menu.
The maximum load at 110 V is 1100 W and 10 A. Do not exceed these limits!
The maximum load at 230 V is 2300 W and 10 A. Do not exceed these limits!
After a power failure, the in-wall relay returns to the last state before the power
failure.
The in-wall relay is
incompatible
with the wireless repeater and cannot be saved
in the backup configuration file.
The in-wall relay is a new edition (version 2, available since the end of 2014).