MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-218
PRI Facilities
3
PC Procedure
→
→
→
→
Type slot no. (1–17)
→
→
Select timer/counter
→
7
+
%
I
→
Type no. of
ms/octets/and so on
→
→
→
→
→
Procedure: Timers and Counters
3
Console Display/Instructions
Additional Information
PC
1.
Select the
Lines
and
Trunks
menu.
Table 3-3.
Timers and Counters
Timer/Counter
Purpose
Factory Setting
Valid Range
T200 Timer
Maximum response time
1 second
1,000 to 3,000 ms
T203 Timer
Maximum time
30 seconds
1 to 60 seconds
N200 Counter
Maximum transmissions
3 transmissions
1 to 5 transmissions
N201 Counter
Maximum octets
260 octets
16 to 260 octets
K Counter
Maximum outstanding
I-frames
7 frames
1 to 15 frames
T303 Timer
Set up timeout
4 seconds
4 to 12 seconds
T305 Timer
Disconnect timeout
4 seconds
4 to 30 seconds
T308 Timer
Release timeout
4 seconds
4 to 12 seconds
T309 Timer
Signal loss
90 seconds
30 to 120 seconds
T310 Timer
Call Proc. timeout
60 seconds
2 to 120 seconds
T313 Timer
Connect timeout
4 seconds
4 to 60 seconds
T316 Timer
Restart timeout
120 seconds
30 to 120 seconds
System Programming: >
Make a selection
System
Extensions
SysRenumber
Options
Operator
Tables
LinesTrunks
AuxEquip
Exit
NightSrvce