MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-46
System Operator Positions
3
DLC Operator Positions
3
DLC operator positions can be assigned to the first and fifth extension jacks on
the first modules with either digital or analog multiline extension jacks. A
maximum of eight DLC operator positions can be assigned. Any combination of
operator positions can be assigned as long as there are no more than four QCC
operator positions and no more than a total of eight operator positions.
Use this procedure to specify extensions that serve as central answering positions
for all incoming calls, either for Call Management Systems (CMSs) connected to
operator extension jacks, or as calling group supervisor extensions. (You do not
need to use this procedure in a Key or Behind Switch system unless you have
more than one DLC position.) For a new system, remove the factory-set DLC
operator position assignment for any telephone not used as an operator position.
Lines and trunks are assigned to individual buttons.
The system programming console can have several incoming calls ringing
simultaneously.
Each CMS requires two DLC operator positions to connect the equipment and
one position to serve as CMS supervisor.
Summary: Identify or Remove DLC Operator
Positions
3
Programmable by
System Manager
Mode
All
Idle Condition
System idle
Planning Form
2a, System Numbering: Extension Jacks
Factory Setting
Type: DLC
Valid Entries
First or fifth extension jack on MLX module (maximum:
two per module; maximum: eight DLCs per system)
Inspect
Yes
Copy Option
No
Console Procedure
Operator
→
Positions
→
Direct
Line
→
Dial ext.
no.
→
Enter
or
Delete
→
Store
All
PC Procedure
→
→
→
Type ext. no.
→
or
→
Содержание MERLIN LEGEND Release 7.0