MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-192
PRI Facilities
3
B-channels must be identified by control unit slot and port numbers since they are
not associated with a line/trunk number or a logical ID.
PRI B-channel groups programmed for line routing perform similarly to loop-start
trunks. PRI B-channel groups programmed for dial plan routing perform similarly
to DID trunks.
NOTE:
If more lines than B-channels are assigned to a B-channel group, users
may experience situations where a line that is idle is not able to seize a
B-channel. The user receives a fast busy tone.
Summary: B-Channel Groups
3
Programmable by
System Manager
Mode
Hybrid/PBX, Key
Idle Condition
Not required
Planning Form
3b, Incoming Trunks: DS1 Connectivity (100D module)
Factory Setting
Not applicable
Valid Entries
Group numbers (1 to 80)
Inspect
Yes
Copy Option
No
Console Procedure
To program a single-line/trunk:
LinesTrunks
→
PRI
→
B-ChannlGrp
→
B
Channels
→
Dial group no. (1–80)
→
Enter
→
Dial
B-channel slot and port nos.
→
Enter
→
Lines
→
Dial
group no.
→
Enter
→
Entry
Mode
→
Dial line/trunk
no.
→
Enter
→
Exit
→
Exit
→
Exit
To program a block of lines/trunks:
LinesTrunks
→
PRI
→
B-ChannlGrp
→
B
Channels
→
Dial group no. (1–80)
→
Enter
→
Dial B-channel slot and port no.
→
Enter
→
Lines
→
Dial group no.
→
Enter
→
Select specific
lines/trunks
→
Toggle LED on/off
→
Exit
→
Exit
→
Exit