MERLIN LEGEND Communications System Release 7.0
System Programming
555-670-111
Issue 1
April 1999
Programming Procedures
3-136
DS1 Facilities
3
Signaling Mode
3
Use this procedure to specify the signaling for the 100D module as robbed-bit or
common-channel signaling.
NOTE:
This procedure is needed only for T1 facilities; common-channel signaling
is set automatically for PRI facilities. For 100D-U modules, however, this
procedure is not valid for T1 facilities.
Summary: Signaling Mode
3
Programmable by
System Manager
Mode
All
Idle Condition
100D module idle
Planning Form
3b, Incoming Trunks: DS1 Connectivity (100D module)
Factory Setting
Robbed bit
Valid Entries
Robbed Bit, Common Channel
Inspect
No
Copy Option
No
Console Procedure
LinesTrunks
→
LS/GS/DS1
→
Dial slot no. (1–17)
→
Enter
→
Signaling
→
Select type of signaling (Robbed
Bit or Common Channel)
→
Enter
→
Exit
→
Exit
PC Procedure
→
→
Type slot no. (1–17)
→
→
→
Select
type of signaling (Robbed Bit or Common Channel)
→
→
→
Procedure: Signaling Mode
3
Console Display/Instructions
Additional Information
PC
1.
Select the
Lines
and
Trunks
menu.
System Programming: >
Make a selection
System
Extensions
SysRenumber
Options
Operator
Tables
LinesTrunks
AuxEquip
Exit
NightSrvce