Office-Alarm Interface
....................................................................................................................................................................................................................................
Station Alarms
Prompt:
Immediate maintenance action is required because a
primary-system service is affected.
Deferred:
Maintenance action is required but may be deferred
because no primary-system service is affected.
Cable Data
Cable
Description
Remarks
Type
8x2x0.4 mm +
Screen
Comcode
407128107
DC Resistance
145
Ω
/1000 m
Cable Length
If the maximum drop in voltage is 1 V at 50 mA
and the maximum cable resistance is 145
Ω
/1000
m per single wire, the maximum length will be
138
m
.
Color Code
“Multicore Low-Current Cables” (A-32)
Connector Data
Type of
Connector
D-SUB pin, 15p solder
Code no. of
Connector
407362755
Code no. of
Hood
405528217
Inner-Ferrule No.
403373624
Outer-Ferrule
No.
403373632
Mounting
Instructions
“Mounting of the Shielded Cable Hood for a
D-SUB Connector ” (A-7)
Block and Terminal Diagrams
....................................................................................................................................................................................................................................
5 - 1 8
Lucent Technologies - Proprietary
See notice on first page
365-312-761
Issue 1, May 2004