![Lucent Technologies IP-GE/2 Скачать руководство пользователя страница 128](http://html.mh-extra.com/html/lucent-technologies/ip-ge-2/ip-ge-2_installation-manual_1946302128.webp)
Mini-Balun 75/120
Ω
Termination
....................................................................................................................................................................................................................................
Mini-Balun 75/120
Ω
Connectors
A mini-balun connector can be placed at the open end of the prefab
cables.
Connector Data
Description
Panel
mounting
Comcode
APT1000, Male, Straight
yes
848341673
APT1000, Male, 45°
yes
848341749
1.6/5.6, Female, Straight
yes
848341772
1.6/5.6, Male, Straight
no
848341756
1.0/2.3, Female, Straight
yes
848341814
1.2/2.3, Male, Straight
no
848341806
Type 43, Male, Straight
yes
848341830
Type 43, Female, Straight
no
848341822
BNC, Female, Straight
yes
848341798
BNC, Male, Straight
no
848341780
Preparation steps
Important!
Always connect the overall braid *1 of the STP or
UTP cables to the frame ground.
............................................................................................................................................................
1
Disassemble the rear-end components from the mini-balun.
............................................................................................................................................................
2
Fit the nut and the outer cover onto the cable in that order.
............................................................................................................................................................
3
Strip the 11mm jacket and foil from the end of the single STP cable.
............................................................................................................................................................
4
Fit the washer over the stripped wires and the drain wire and then
fold the drain wire back over the washer and around the cable sheath
(only STP cable).
............................................................................................................................................................
5
Insert the wires into the holes in the small end of the stuffer cap that
are marked “A” and “B”.
Assembly Instructions
....................................................................................................................................................................................................................................
A - 2
Lucent Technologies - Proprietary
See notice on first page
365-312-761
Issue 1, May 2004