9. Object Dictionary
9-54
0x2510
Off-line Gain Tuning Direction
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
UINT
0 to 1
0
-
RW
No
Servo off
Yes
This specifies the movement direction when performing the Off-line Gain Tuning. Set the function
properly according to the condition of the apparatus section.
Setting values
Setting details
0
Drive in the forward direction
1
Drive in the reverse direction
0x2511
Off-line Gain Tuning Distance
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
UINT
1 to 10
5
-
RW
No
Servo off
Yes
It specifies the distance when performing the off-line gain tuning. The larger the setting value is, the
longer the movement distance becomes. Set the distance properly according to the condition of the
apparatus section. Make sure to secure enough distance (more than one revolution of motor) prior to
gain tuning.
0x2512
Disturbance Observer Gain
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
UINT
0 to 100
50
%
RW
No
Servo off
Yes
(It will be supported later)
0x2513
Disturbance Observer Filter Time Constant
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
UINT
0 to 1000
10
0.1
ms
RW No
Servo
off
Yes
(It will be supported later)
0x2514
Current Controller Gain
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
UINT
1 to 150
100
%
RW
No
Servo off
Yes
This specifies the current controller gain. Lowering the setting value will reduce the noise, but the
drive's responsiveness decreases as well.
Содержание XDL-L7NH Series
Страница 2: ......
Страница 12: ......
Страница 21: ...1 Product Configuration 1 9 1 3 2 Servo Motor Parts 80 Flange or below 130 Flange or higher ...
Страница 43: ...2 Wiring and Connection 2 21 ...
Страница 52: ...2 Wiring and Connection 2 30 2 6 5 EnDat 2 2 Encoder Signaling Unit Wiring Servo Motor Encoder Servo Drive ...
Страница 58: ......
Страница 68: ......
Страница 75: ...4 CiA402 Drive Profile 4 7 Internal Block Diagram of CSP Mode ...
Страница 78: ...4 CiA402 Drive Profile 4 10 Internal Block Diagram of PP Mode ...
Страница 86: ...4 CiA402 Drive Profile 4 18 Internal Block Diagram of PV Mode ...
Страница 118: ...5 Drive Application Functions 5 10 ...
Страница 148: ......
Страница 283: ...10 Product Specifications 10 23 SGP Series APM SGP110G ...
Страница 284: ...10 Product Specifications 10 24 SGP Series APM SGP150G ...
Страница 288: ...10 Product Specifications 10 28 FGP Series APM FGP110G ...
Страница 294: ...10 Product Specifications 10 34 XDL L7NHB150U Weight 15 5 kg including the cooling fan ...
Страница 336: ...13 Appendix 13 20 5 Turn on the power again and verify if the firmware is updated ...
Страница 345: ...13 Appendix 13 29 Check firmware version The firmware version is lower than current one can t be downloaded ...
Страница 346: ......