5 - 69
System
Faults
Possible causes
Solutions
Electric
System
Battery does not
charge
▲
Abnormal wiring
▲
Alternator failure
▲
Lack of fan belt tension or
broken
▲
Abnormal battery
▲
Check the tightening state
of terminals and ground
▲
Repair or replace
▲
Adjust fan belt tension or
replace
▲
Replace
Headlight is dark.
▲
Battery capacity is low
▲
Bad wiring and contact
▲
Charge or replace
▲
Check and repair
Headlight is not ON.
▲
Light bulb cut-off
▲
Fuse blown
▲
Replace
▲
Check the cause, and
replace it
Horn does not sound.
▲
Switch failure
▲
Abnormal wiring
▲
Horn failure
▲
Replace
▲
Repair
▲
Replace
Turn signal light does
not work.
▲
Light bulb cut-off
▲
Bad connection
▲
Fuse blown
▲
Replace
▲
Tighten terminals
▲
Check the cause, and
replace it
Cold start aid indicator
is not ON.
▲
Relay and timer damaged
▲
Bad connection of preheat
plug wiring
▲
Replace
▲
Check and tighten
Other illuminating light
or indicator is not ON.
▲
Fuse blown
▲
Light bulb cut-off
▲
Check the cause, and
replace it
▲
Replace
Содержание XP8084
Страница 1: ...LS TRACTOR OPERATOR S MANUAL XP8084 XP8094 XP8101 ...
Страница 2: ......
Страница 4: ......
Страница 12: ......
Страница 70: ......
Страница 80: ...3 10 SCR inducement strategy Low DEF level ...
Страница 81: ...3 11 SCR inducement strategy poor DEF quality ...
Страница 82: ...3 12 SCR inducement strategy SCR System tampering detection ...
Страница 178: ...4 36 Attaching points for Front end loader When attaching the front end loader refer to the drawings as below Unit mm ...
Страница 188: ......
Страница 191: ...5 3 Identification markings Metric hex bolt head 1 Manufacturer s identification 2 Property class GS 8 8 1 2 ...
Страница 261: ...5 73 Attachment ...
Страница 262: ......
Страница 280: ......
Страница 281: ...8 1 8 Dimension and Specification 1 Cabin type Unit mm When applying front tire 12 4 24 8PR rear tire 16 9 34 8PR ...
Страница 282: ...8 2 2 Roll bar type Unit mm When applying front tire 12 4 24 8PR rear tire 16 9 34 8PR ...
Страница 287: ......
Страница 288: ......