Chapter 14. COM Option (RS-485)
14-13
Address
16bit
10bit
Code Parameter
Initial
Max.
Min.
D221
53793
P 33 Trip select
0
3
0
D222 53794 P
34
Power-on
run
0
1
0
D223 53795 P
35
RST
restart
0
1
0
D224
53796
P 36 Speed Search
0
50
0
D225 53797 P
37
SS
Sup-Curr
100 200
80
D226 53798 P
38
Retry
number
0
10
0
D227 53799 P
39
Retry
delay
10
600
0
D228 53800 P
40
Motor
select
0
2
0
D229 53801 P
41
Pole
number
4
12
2
D22A 53802 P
42
Rated-Slip
freq.
200 1000
0
D22B 53803 P
43
Rated-Curr
10
255
0
D22C 53804 P
44 Noload-Curr
5
255
0
D22D 53805 P
45 Carrier
freq
30
100
10
D22E 53806 P
46
Control
Mode
0
2
0
D22F 53807 P
47
PI
P-gain
3000 9999
0
D230 53808 P
48
PI
I-gain
100 3200
10
D232 53810 P
50
PI
F-gain
0
9999
0
D233
53811
P 51 PI output freq. H limit
6000
Max. Freq.
PI output freq.L limit
D234
53812
P 52 PI output freq. L limit
50
PI output freq. H
limit
startFreq.
D235 53813 P
53
PowerOn
disp
0
15
0
D236
53814
P 54 Rpm disp Gain
100
1000
1
D237
53815
P 55 AI input filter cont
10
9999
0
D238
53816
P 56 AI min. Input(v/i)
0
AI max. inupt
0
D239
53817
P 57 AI min. input freq.
0
Max. Freq.
0
D23A
53818
P 58 AI max. Input(v/i)
1000
1000
AI min. input
D23B
53819
P 59 AI max. input freq.
6000
Max. Freq.
0
D23C
53820
P 60 Volume input filter cont
10
9999
0
D23D
53821
P 61 Volume min. input
0
Vol. max. input
0
D23E
53822
P 62 Volume input min. freq.
0
Max. Freq.
0
D23F
53823
P 63 Volume max. input
1000
1000
Vol. min. input
D240
53824
P 64 Volume input max. freq.
6000
Max. Freq.
0
D241
53825
P 65 Anal speed command lost criteria
0
2
0
D242 53826 P
66
P1
define
0
24
0
Содержание SV-iE5 Series