4/29/2020
Loongson 3A3000 / 3B3000 Processor User Manual
107
131
Thsens_int_ctrl_Hi
0x3ff01460
RW
[23:16]: Hi_gate1: high temperature threshold 1, exceeding this temperature will generate an interrupt
[24:24]: Hi_en1: High temperature interrupt enable 1
[27:26]: Hi_Sel1: Select the temperature sensor input source for high temperature interrupt 1
[39:32]: Hi_gate2: High temperature threshold 2, above this temperature will generate an interrupt
[40:40]: Hi_en2: High temperature interrupt enable 2
[43:42]: Hi_Sel2: Select the temperature sensor input source for high temperature interrupt 2
[55:48]: Hi_gate3: High temperature threshold 3, exceeding this temperature will generate interrupt
[56:56]: Hi_en3: High temperature interrupt enable 3
[59:58]: Hi_Sel3: Select the temperature sensor input source for high temperature interrupt 3
Page 136
Godson 3A3000 / 3B3000 Processor User Manual • Volume 1
132
Thsens_int_ctrl_Lo
0x3ff01468
RW
Temperature sensor low temperature interrupt control register
[7: 0]: Lo_gate0: low temperature threshold 0, below this temperature will generate an interrupt
[8: 8]: Lo_en0: Low temperature interrupt enable 0
[11:10]: Lo_Sel0: Select the temperature sensor input source for low temperature interrupt 0
[23:16]: Lo_gate1: low temperature threshold 1, below this temperature will generate an interrupt
[24:24]: Lo_en1: Low temperature interrupt enable 1
[27:26]: Lo_Sel1: Select the temperature sensor input source for low temperature interrupt 1
[39:32]: Lo_gate2: Low temperature threshold 2, below this temperature will generate an interrupt
[40:40]: Lo_en2: Low temperature interrupt enable 2
[43:42]: Lo_Sel2: Select the temperature sensor input source for low temperature interrupt 2
[55:48]: Lo_gate3: Low temperature threshold 3, below this temperature will generate an interrupt
[56:56]: Lo_en3: Low temperature interrupt enable 3
[59:58]: Lo_Sel3: Select temperature sensor input source for low temperature interrupt 3
Thsens_int_status / clr
0x3ff01470
RW
Interrupt status register, write any value to clear the interrupt
[0]: High temperature interrupt trigger
[1]: Low temperature interrupt trigger
Page 137