Table of ConTenTs

safeTy ProCedures

!

 WarnInG

• Before using this product, read and understand the instructions.

• All work must be performed by qualified personnel trained in the proper application, installation, and 

maintenance of equipment and/or systems in accordance with all applicable codes and ordinances.

• When handling electronic components and boards, always use proper Electrostatic Discharge (ESD) equipment 

and follow the proper procedures

• Make sure that all necessary safety precautions have been taken. 

• Provide for proper ventilation, temperature control, fire prevention, evacuation, and fire management.

• Provide easy access to the appropriate fire extinguishers for your product. 

• Consult with your local fire department, state, and local codes to ensure adequate preparation.

• Read this manual as well as all the literature provided in your owner’s packet.

• Save these instructions for future reference.

• Failure to follow the instructions set forth in this publication could result in property damage, personal injury, or 

death from fire and/or explosion, or other hazards that may be associated with this type of equipment.

The most current English versions of all Liquid Controls publications are available on our web site, 

www.lcmeter.com

It is the responsibility of the local distributor to provide the most current version of LC manuals, instructions, and 

specification sheets in the required language of the country, or the language of the end user to which the products are 

shipping. If there are questions about the language of any LC manuals, instructions, or specification sheets, please 

contact your local distributor.

Publication updates and Translations

be Prepared

!

 WarnInG

Power, input, and output (I/O) wiring must be in accordance with the area classification for which it is used (See Safety 

Markings sections). This may require using connections or other adaptations in accordance with the requirements of the 

authority having jurisdiction.
To comply with UL Listing requirements, Class 2 power supply, or an isolation power source and overcurrent protective 

device rated 5 Amp max, are required to be installed in the field. (Pour être conforme aux exigences UL, une alimentation 

électrique de classe 2 ou une alimentation électrique isolée et comportant un dispositif de protection contre la surtension 

de 5 ampères ou moins sont requises pour l’installation.) Peripheral equipment must be suitable for the hazardous 

location where it is installed. (L'équipement périphérique doit être adapté des endroits dangereux où il est installé.)

WARNING:

 

Explosion Hazard:

  

(AVERTISSEMENT:

 

Risque d’explosion)

Substitution of components may impair suitability for Class I, Division 2 applications.  (La substitution des composantes 

peut altérer la conformité aux applications de Classe I, Division 2.)
When in hazardous locations, turn power OFF before replacing or wiring modules. (Lorsque dans des endroits 

dangereux, couper le courant avant de remplacer ou de câbler les modules.)
Do NOT disconnect equipment unless power has been switched OFF or the area is known to be Non-Hazardous.  (Ne 

pas déconnecter l’équipement sans couper l’alimentation ou sans s’assurer que la zone est non-dangereuse.)

WARNING: 

Use 3.5 in • lb (0.4 N • m) torque when tightening terminal block screws.

WARNINGS:

 (For IECEx, INMETRO, and ATEX installations only)

Protect from impact - Must only be installed in areas with low risk of mechanical impact.

observe national and 

local Codes

Before disassembly of any meter or accessory component:

 

ALL INTERNAL PRESSURES MUST BE RELIEVED AND ALL LIQUID DRAINED FROM 

 

THE SYSTEM IN ACCORDANCE WITH ALL APPLICABLE PROCEDURES

 

 

-Pressure must be 0 (zero) psi. 

 

 

-Close all liquid and vapor lines between the meter and liquid source.

Failure to follow this warning could result in property damage, personal injury, or death from fire and/or explosion, or other 

hazards that may be associated with this type of equipment.

!

 WarnInG

safely evacuate 

Piping system

 

 InTroduCTIon

Safety Procedures  ................................................... 3

ESD Protection ......................................................... 4

Safety Markings ....................................................... 5

Specifications  ..........................................................

6

Dimensions ..............................................................

7

LectroCount LCR-II Overview ..................................

8

Meter System Overview ...........................................

9

 

 InsTallaTIon

Installation Overview ...............................................

11

LectroCount Ground Strap Kit ................................. 13

LectroCount LCR-II Mounting  ................................ 15

Routing LCR-II Data and Power Cables  ................

18

Electronic Temperature Volume Compensation ......

19

Valves ...................................................................... 20 

Optical Air and Vapor Eliminators ............................ 24

Pulse Output Device (POD) .................................... 25

Single Channel Pulse Outputs ................................ 25

Differential Pressure (∆P) Transducer ..................... 26

Remote Display and Auxiliary Outputs .................... 27

Printers .................................................................... 28

Data Communications ............................................. 29

Power Installation .................................................... 30

Post Installation ....................................................... 33

    

 bIll of MaTerIals

External Components .............................................. 34

Internal Components ............................................... 35

CPU Board .............................................................. 36

Содержание LectroCount LCR-II E3657 Series

Страница 1: ...LectroCount LCR II Installation Liquid Controls An IDEX Energy Fuels Business Operation EM150 21 E3657 E3658 Series LectroCount LCR II SELECT INCREASE Gallons S3...

Страница 2: ...se 2 ou une alimentation lectrique isol e et comportant un dispositif de protection contre la surtension de 5 amp res ou moins sont requises pour l installation Peripheral equipment must be suitable f...

Страница 3: ...a known good ground less than 1 Use a 12 ga or larger stranded wire Fixed Installations LectroCount housings directly mounted to the meter are attached to the earth ground through the meter via the ta...

Страница 4: ...ower cable Specifications Safety Tag Markings EU Explosive Atmospheres symbol This equipment has been found to comply with the European Directive for Equipment For Potentially Explosive Atmospheres 94...

Страница 5: ...8 Dimensions Side Front Top 15 9 94 5 19 LectroCount LCR II 13 7 5 8 04 10 5 70 Rear...

Страница 6: ...ghts Measures custody transfer product delivery and ticket generation Metrological data collection Presetting by volume Multiple production selection Security settings Air and vapor elimination with p...

Страница 7: ...y standard for many applications Multi layered tickets are available to provide a physical record for both customers and business records The Epson roll printer is ideal for recording multiple custody...

Страница 8: ...xidation from the ground strap contact point Lock washers should penetrate any paint to ensure a good electrical connection Ensure a Good Ground LectroCount Ground Strap Kit 82185 Install the LectroCo...

Страница 9: ...nd discharge line valve nozzle 8 Leave the discharge line valve nozzle open while working on the system 1 Close the belly valve of the supply tank 2 Close the valve on the vapor return line 3 Close th...

Страница 10: ...es Data and Power Cable The LCR II shipment typically includes a gray 40 power cable and a 40 black data cable prewired to terminal blocks on the LCR II CPU board On typical truck installations the ca...

Страница 11: ...Preset Valve Single Stage Electro Pnuematic Valve with V 7 Valve S1 Solenoid V 7 Valve Electro Pnuematic Actuator LectroCount LCR II Gallons A2859 11 Block Valve and 3 Way Solenoid Single Stage 3 Way...

Страница 12: ...eries Electro Pnuematic Valve Electro pnuematic valves use a S1 solenoid operated valve mounted to a pneumatic actuator to open and close a V 7 valve These valves are typically used in high viscosity...

Страница 13: ...llations When ordered as part of a meter system with a LCR II Liquid Control s optical air and vapor eliminators are bolted onto the strainer and wired to the LCR II at the factory Optical air and vap...

Страница 14: ...d PN 81944 that mounts directly to the LCR II CPU board Typically a P transducer operates in conjuction with a shutdown device such as a valve or a dead man The shutdown control must be wired to the L...

Страница 15: ...llation J1 RS 232 A Liquid Controls meter system with a LCR II typically includes an Epson slip printer or roll printer Installation is the same for both printers LCR II s are typically shipped with a...

Страница 16: ...ng Device B RS 485 J2 24 red J2 25 violet Multimeter Network B RS 485 J2 24 red J2 25 violet Power Installation Power Installation Overview When you have made all of the data connections and finished...

Страница 17: ...r the LCR II has been installed check to make sure that it powers up correctly The LCR II display and the printer power light should come on when the truck s ignition is turned to the ON or to the ACC...

Страница 18: ...er provided and held in place with the cotter pin provided The control switch on the front of the LCR II is also sealed with an O ring and held in place by a bushing secured with three socket head cap...

Страница 19: ...sher 2 81994 PULSER 100 PPR Pulser Field Install Kit 82597 08189 Flat Washer 08201 O ring 2 Optional Items not shown Description Part Number Roll Printer Extension Cable 71237 Flash Cable 81885 Lap Pa...

Страница 20: ......

Страница 21: ...2014 Liquid Controls Pub No 500392 7 14 105 Albrecht Drive Lake Bluff IL 60044 2242 1 800 458 5262 847 295 1050 Fax 847 295 1057 www lcmeter com...

Отзывы: