background image

36

37

bIll of MaTerIals - InTernal CoMPonenTs

PRINTER

SERIAL 485

TERMINAL

POWER

COUNTER

MH1

CTS RXD TXD RTS

GND

GND

485+A

485-B

CTS RXD TXD RTS +VP

EARTH

AUX OUTPUTS

PULSE INPUTS

AUX I/O

GND

GND

GND

IN 1

OUT1

OUT2

OUT3

TEMPERATURE PROBE

ASSY

84040 REV.

RTD+S

RTD-D1

RTE-S

RTD+D

OUT4

OUT5

IN 2

IN 3

IN 4

+5V OUT

+VP

+VP

PGND

OUT6 +VP

SOL

+VP

PGNDOUT7

+VF

+VF

IN5

OUT8

GND

GND

+12-24V

ACC

MH4

C1

J20

J6

J3

J2

J1

J7

J12

J15

P1

TP1

J5

J14

J18

J19

J10

J17

J11

J7

C2

MH5

MH3

MH2

A

B

11

10

1213

52

53

54

55

56

24

25

81833

Hollow O-ring Seal

81330

Coiled Cable Handset

81513040-

UL

81713040-

IECEx / INMETRO / ATEX

Data Cable

71319

Desiccant

840405

CPU Board Assy

08158

Screw #6-32 x½" (4)

81512-

UL

81712-

IECEx / INMETRO / ATEX

Power Cable 

08254

Ground Screw #8-32 x ¼"

81836

Ground Strap w/

Screws and Washers

81832

Rotary Switch & Harness Assy

Pulser field Install Kit

82597

09380

Nylon Washer (2)

81994

PULSER, 100 PPR

Pulser Field Install Kit

82597

08189

Flat Washer

08201

O-ring (2)

optional Items

 

(not shown)

description

Part number

Roll Printer Extension Cable

71237

Flash Cable

81885

Lap Pad Adapter

81514

Lap Pad

E40301

Lap Pad with Adapter

E403012

bIll of MaTerIals - CPu boards

81324

J1–5-Pin Connector 

81456

J3–8-Pin Connector

81321

J13–6-Pin Connector

81322

J14–4-Pin Connector

84049

J6–4-Pin Connector

81392

J8–8-Pin Connector

81391

J12–7-Pin Connector

81837

J15–5-Pin Connector

PRINTER

SERIAL 485

TERMINAL

POWER

COUNTER

MH1

CTS RXD TXD RTS

GND

GND

485+A

485-B

CTS RXD TXD RTS +VP

EARTH

AUX OUTPUTS

PULSE INPUTS

AUX I/O

GND

GND

GND

IN 1

OUT1

OUT2

OUT3

TEMPERATURE PROBE

ASSY

84040 REV.

RTD+S

RTD-D1

RTE-S

RTD+D

OUT4

OUT5

IN 2

IN 3

IN 4

+5V OUT

+VP

+VP

PGND

OUT6 +VP

SOL

+VP

PGNDOUT7

+VF

+VF

IN5

OUT8

GND

GND

+12-24V

ACC

MH4

C1

J20

J6

J3

J2

J1

J7

J12

J15

P1

TP1

J5

J14

J18

J19

J10

J17

J11

J7

C2

MH5

MH3

MH2

A

B

11

10

1213

52

53

54

55

56

24

25

840405 CPu board

The J2 terminal block is 

permanantly attached to the 

CPU board.

Do Not Try To Remove J2

Содержание LectroCount LCR-II E3657 Series

Страница 1: ...LectroCount LCR II Installation Liquid Controls An IDEX Energy Fuels Business Operation EM150 21 E3657 E3658 Series LectroCount LCR II SELECT INCREASE Gallons S3...

Страница 2: ...se 2 ou une alimentation lectrique isol e et comportant un dispositif de protection contre la surtension de 5 amp res ou moins sont requises pour l installation Peripheral equipment must be suitable f...

Страница 3: ...a known good ground less than 1 Use a 12 ga or larger stranded wire Fixed Installations LectroCount housings directly mounted to the meter are attached to the earth ground through the meter via the ta...

Страница 4: ...ower cable Specifications Safety Tag Markings EU Explosive Atmospheres symbol This equipment has been found to comply with the European Directive for Equipment For Potentially Explosive Atmospheres 94...

Страница 5: ...8 Dimensions Side Front Top 15 9 94 5 19 LectroCount LCR II 13 7 5 8 04 10 5 70 Rear...

Страница 6: ...ghts Measures custody transfer product delivery and ticket generation Metrological data collection Presetting by volume Multiple production selection Security settings Air and vapor elimination with p...

Страница 7: ...y standard for many applications Multi layered tickets are available to provide a physical record for both customers and business records The Epson roll printer is ideal for recording multiple custody...

Страница 8: ...xidation from the ground strap contact point Lock washers should penetrate any paint to ensure a good electrical connection Ensure a Good Ground LectroCount Ground Strap Kit 82185 Install the LectroCo...

Страница 9: ...nd discharge line valve nozzle 8 Leave the discharge line valve nozzle open while working on the system 1 Close the belly valve of the supply tank 2 Close the valve on the vapor return line 3 Close th...

Страница 10: ...es Data and Power Cable The LCR II shipment typically includes a gray 40 power cable and a 40 black data cable prewired to terminal blocks on the LCR II CPU board On typical truck installations the ca...

Страница 11: ...Preset Valve Single Stage Electro Pnuematic Valve with V 7 Valve S1 Solenoid V 7 Valve Electro Pnuematic Actuator LectroCount LCR II Gallons A2859 11 Block Valve and 3 Way Solenoid Single Stage 3 Way...

Страница 12: ...eries Electro Pnuematic Valve Electro pnuematic valves use a S1 solenoid operated valve mounted to a pneumatic actuator to open and close a V 7 valve These valves are typically used in high viscosity...

Страница 13: ...llations When ordered as part of a meter system with a LCR II Liquid Control s optical air and vapor eliminators are bolted onto the strainer and wired to the LCR II at the factory Optical air and vap...

Страница 14: ...d PN 81944 that mounts directly to the LCR II CPU board Typically a P transducer operates in conjuction with a shutdown device such as a valve or a dead man The shutdown control must be wired to the L...

Страница 15: ...llation J1 RS 232 A Liquid Controls meter system with a LCR II typically includes an Epson slip printer or roll printer Installation is the same for both printers LCR II s are typically shipped with a...

Страница 16: ...ng Device B RS 485 J2 24 red J2 25 violet Multimeter Network B RS 485 J2 24 red J2 25 violet Power Installation Power Installation Overview When you have made all of the data connections and finished...

Страница 17: ...r the LCR II has been installed check to make sure that it powers up correctly The LCR II display and the printer power light should come on when the truck s ignition is turned to the ON or to the ACC...

Страница 18: ...er provided and held in place with the cotter pin provided The control switch on the front of the LCR II is also sealed with an O ring and held in place by a bushing secured with three socket head cap...

Страница 19: ...sher 2 81994 PULSER 100 PPR Pulser Field Install Kit 82597 08189 Flat Washer 08201 O ring 2 Optional Items not shown Description Part Number Roll Printer Extension Cable 71237 Flash Cable 81885 Lap Pa...

Страница 20: ......

Страница 21: ...2014 Liquid Controls Pub No 500392 7 14 105 Albrecht Drive Lake Bluff IL 60044 2242 1 800 458 5262 847 295 1050 Fax 847 295 1057 www lcmeter com...

Отзывы: