background image

6

7

Materials of Construction

 

• Aluminum Alloy ADC12

 

• Powder Coat: Corro-Coat PE 74-141 Polyester

Weight

  

• 8.4 lbs (3.8 kg)

Display Elements

 

• Liquid crystal display (LCD)

Cable Entry

 

• ½″ NPT (5)

 

• ¾″ NPT (2)

Ambient Temperature Rating

 

• -40 to 158 °F (-40 to 70 °C)

 

• -4 to 158 °F (-20 to 70 °C)  

for IECEx / INMETRO / ATEX

Mechanical

Input/output

Communications

 

• RS-232: EIA-232E standard

 

 

RS-485:

 

SAE J1708 standard

Auxiliary 1 Output

 Current 

sinking capability

:

 1 A

Auxiliary 2 Output

 Current 

sinking capability

:

 150 mA

Solenoid 1 Output

 Voltage:

 

10.2 to 27.2 VDC

 Current

:

 1 A 

maximum

Solenoid 2 Output

 Voltage:

 

10.2 to 27.2 VDC

 Current

:

 1 A 

maximum

Solenoid 3 Output

 Voltage:

 

10.2 to 27.2 VDC

 Current

:

 1 A 

maximum

Optical Sensor

 Voltage:

 

10 to 28 VDC

 Current

:

 0.5 A 

maximum

RTD Temperature Probe

 

• 4 wire platinum sensor

 

• 100 Ω resistance at 0 ºC

 

• 138.5 Ω resistance at 100 ºC

Printer (Epson Model 295)

 Voltage:

 24 VDC

 Current

:

 0.8 A

 

maximum

 

Operating Temperature:

 -22 to 104 ºF (-30 to 40 ºC)

Remote Electronic Display

 

• 1 A 

sinking capability

electrical

Input Voltage

 Voltage:

 

9 to 28 VDC

 Current

:

 4.5 A 

maximum

  

 

 

 

 

 

 

(including solenoid valves)

Pulse Output

 Voltage 

peak to peak

:

 

 5 to 28 V

 Frequency 

maximum

:

 

10,000 Hz

Scale Pulse Output

 Current 

sinking capability

:

 150 mA 

Electrical Protection 

 

• 5 A fuse 

on power cable

sPeCIfICaTIons

safeTy TaG MarKInGs

EU Explosive Atmospheres symbol
This equipment has been found to comply with the European Directive for Equipment For Potentially Explosive Atmospheres 94/9/

EC (ATEX), Certification Scheme for Explosive Atmospheres of INTERNATIONAL ELECTROTECHNICAL COMMISSION (IECEx) 

and Brazil’s Portaria 179, as evidenced by the certificates listed on the name tag subject to the following conditions of use: 1) Wipe 

with damp cloth before opening the cover; 2) install only in areas with low risk of mechanical impact

II

Suitable for use in surface (not mine) installations

3 G

Equipment for explosive gas atmospheres, having a “high” level of protection, which is not a source of ignition in normal operation 

or during expected malfunctions 

ex na ic

Explosion protection is provided by non-sparking device (nA) and intrinsic safety (ic)

IIb

Gas group

 

T5

Temperature class for surface temperature limitations. T5 is ≤ 100ºC

Gc

Equipment protection level per IEC 60079-0, EN 60079-0, and ABNT NBR IEC 60079-0

-20°C ≤ T

amb

 ≤ 70°C

Safe limits of ambient temperature

IP66

Ingress protection: dust tight and protected against powerful water jetting

Brazil’s INMETRO Mark

Consult factory for current compliance status.

LectroCount LCR-II electronic registers are shipped 

with one of two nameplates. One nameplate is 

applied to UL-Listed units. The other nameplate is 

applied to IECEx / INMETRO / ATEX certified units.

Two Nameplates

Содержание LectroCount LCR-II E3657 Series

Страница 1: ...LectroCount LCR II Installation Liquid Controls An IDEX Energy Fuels Business Operation EM150 21 E3657 E3658 Series LectroCount LCR II SELECT INCREASE Gallons S3...

Страница 2: ...se 2 ou une alimentation lectrique isol e et comportant un dispositif de protection contre la surtension de 5 amp res ou moins sont requises pour l installation Peripheral equipment must be suitable f...

Страница 3: ...a known good ground less than 1 Use a 12 ga or larger stranded wire Fixed Installations LectroCount housings directly mounted to the meter are attached to the earth ground through the meter via the ta...

Страница 4: ...ower cable Specifications Safety Tag Markings EU Explosive Atmospheres symbol This equipment has been found to comply with the European Directive for Equipment For Potentially Explosive Atmospheres 94...

Страница 5: ...8 Dimensions Side Front Top 15 9 94 5 19 LectroCount LCR II 13 7 5 8 04 10 5 70 Rear...

Страница 6: ...ghts Measures custody transfer product delivery and ticket generation Metrological data collection Presetting by volume Multiple production selection Security settings Air and vapor elimination with p...

Страница 7: ...y standard for many applications Multi layered tickets are available to provide a physical record for both customers and business records The Epson roll printer is ideal for recording multiple custody...

Страница 8: ...xidation from the ground strap contact point Lock washers should penetrate any paint to ensure a good electrical connection Ensure a Good Ground LectroCount Ground Strap Kit 82185 Install the LectroCo...

Страница 9: ...nd discharge line valve nozzle 8 Leave the discharge line valve nozzle open while working on the system 1 Close the belly valve of the supply tank 2 Close the valve on the vapor return line 3 Close th...

Страница 10: ...es Data and Power Cable The LCR II shipment typically includes a gray 40 power cable and a 40 black data cable prewired to terminal blocks on the LCR II CPU board On typical truck installations the ca...

Страница 11: ...Preset Valve Single Stage Electro Pnuematic Valve with V 7 Valve S1 Solenoid V 7 Valve Electro Pnuematic Actuator LectroCount LCR II Gallons A2859 11 Block Valve and 3 Way Solenoid Single Stage 3 Way...

Страница 12: ...eries Electro Pnuematic Valve Electro pnuematic valves use a S1 solenoid operated valve mounted to a pneumatic actuator to open and close a V 7 valve These valves are typically used in high viscosity...

Страница 13: ...llations When ordered as part of a meter system with a LCR II Liquid Control s optical air and vapor eliminators are bolted onto the strainer and wired to the LCR II at the factory Optical air and vap...

Страница 14: ...d PN 81944 that mounts directly to the LCR II CPU board Typically a P transducer operates in conjuction with a shutdown device such as a valve or a dead man The shutdown control must be wired to the L...

Страница 15: ...llation J1 RS 232 A Liquid Controls meter system with a LCR II typically includes an Epson slip printer or roll printer Installation is the same for both printers LCR II s are typically shipped with a...

Страница 16: ...ng Device B RS 485 J2 24 red J2 25 violet Multimeter Network B RS 485 J2 24 red J2 25 violet Power Installation Power Installation Overview When you have made all of the data connections and finished...

Страница 17: ...r the LCR II has been installed check to make sure that it powers up correctly The LCR II display and the printer power light should come on when the truck s ignition is turned to the ON or to the ACC...

Страница 18: ...er provided and held in place with the cotter pin provided The control switch on the front of the LCR II is also sealed with an O ring and held in place by a bushing secured with three socket head cap...

Страница 19: ...sher 2 81994 PULSER 100 PPR Pulser Field Install Kit 82597 08189 Flat Washer 08201 O ring 2 Optional Items not shown Description Part Number Roll Printer Extension Cable 71237 Flash Cable 81885 Lap Pa...

Страница 20: ......

Страница 21: ...2014 Liquid Controls Pub No 500392 7 14 105 Albrecht Drive Lake Bluff IL 60044 2242 1 800 458 5262 847 295 1050 Fax 847 295 1057 www lcmeter com...

Отзывы: