lectroCount lCr-II overview 

General InforMaTIon

The Liquid Controls LectroCount LCR-II is a 

microprocessor-based electronic meter register that 

can be used for Weights & Measures approved custody 

transfer actions in mobile or fixed installations. The 

LCR-II can control a meter system as a stand-alone 

unit, or it can be used as a slave to a host contoller such 

as a process controller or an in-cab data management 

system. 

InPuTs

In order to calculate flow measurements from a positive 

displacement meter, the LCR-II receives a pulse input 

from an internally mounted quadrature pulser that is 

mechanically connected to the flow meter (retrofit kits 

are available for installation onto Neptune, Brooks, 

and Smith positive displacement meters). This pulse 

output can also come from a Liquid Controls external 

POD pulser or another pulse generator. In addition to 

the pulse input, the LCR-II is equipped with an input for 

a temperature probe, so the register can compensate 

volume measurements according to the temperature of 

the product. 

ouTPuTs

The LCR-II is equipped with a scaled pulse output, two 

auxiliary outputs, and two solenoids outputs. These 

outputs allow the LCR-II to communicate with meter 

system accessories such as solenoid-controlled valves, 

optical air and vapor eliminators, remote displays, 

printers, and third-party devices. 

CoMMunICaTIons

The LCR-II is capable of interfacing in RS-232 and RS-

485 communication protocols.

HousInG

The LectroCount LCR-II housing and base are aluminum 

die cast and powder coated. The hinge door design 

provides easy access to the internal connections and 

a Weights and Measures sealable fastener opposite 

the hinges. There are seven machined ports, five ½” 

NPT ports and two ¾” NPT ports, on the back of the 

LectroCount LCR-II to provide secure cable connections 

for all external devices.

dIsPlay

The 1” display is a six character, backlit LCD display. 

navIGaTIon Keys 

The LCR-II has two domed navigation keys to perform 

basic configuration and functions. The keys collapse 

and recover to give a tactile, positive confirmation of 

keystrokes. 

seleCTor sWITCH

The selector switch controls basic stop, run, print, and 

shift print delivery functions. To perform calibration 

functions, the cover plate must be removed and the 

selector switch turned to the six o’clock position. 

funCTIonalITy and oPeraTIon

The principle functions of the LectroCount registers 

include:

 

• Calibration (single and multipoint) 

 

• Weights & Measures custody transfer    

 

   (product delivery and ticket generation)

 

• Metrological data collection 

 

• Presetting by volume

 

• Multiple production selection

 

• Security settings

 

• Air and vapor elimination (with proper accessories)

 

• Valve control (with proper accessories)

 

• Electronic temperature volume compensation  

 

  (ETVC) (with proper accessories)

lCr-II overvIeW 

M7 Meter with LectroCount LCR-II Electronic Register, Optical 

Air Eliminator, High Capacity Strainer, and E-7 Valve

Optical Air Eliminator 

Refined Fuels

Mechanical Air 

Eliminator and High 

Capacity Strainer

Optical Vapor Eliminator 

LPG and NH

3

Solenoid Block 

Valve

ETVC Kit

E-7 Valve

Meter system Components

MeTer sysTeM

A Liquid Controls meter system not only accurately 

measures product, it also regulates and purifies product 

flow in order to produce the optimal conditions for 

measurement. Optimal systems typically include an air/

vapor eliminator, strainer, meter, register, and control 

valve. The LectroCount LCR-II, a register, serves as the 

central controller of the meter system. Most components 

in the meter system are hard wired to the LCR-II via data 

communication cables. See manual M100-10.

aIr/vaPor elIMInaTors

Air and vapor eliminators sense and remove air or 

vapor in the piping before it enters the metering system, 

ensuring that only liquid will pass through the meter for 

measurement. Mechanical air eliminators do not require 

a data connection to the LectroCount LCR-II (in LPG 

applications, they are often plumbed to a 3-way solenoid 

which is wired to the LectroCount LCR-II). Optical air 

eliminators use an optical sensor to monitor liquid levels 

and a solenoid-actuated valve to turn the vapor vent on 

and off. The optical sensor and the solenoid valve are 

connected to the LectroCount LCR-II by separate data 

cables. See manuals M300-20 and M300-21.

valves

Valves control the flow through a metering system. They 

open the line to initiate custody transfers and close the 

line to stop custody transfers. Some valves can partially 

close, slowing the flow rate to a dwell flow on preset 

deliveries. By slowing the flow rate, valves can lessen 

the hydraulic shock incurred by the meter system upon 

shut off and provide accurate preset deliveries. Many 

valves use solenoid-operated valves that require a hard 

wired data connection to the LectroCount LCR-II. See 

manuals M400-11 and M400-40.

eleCTronIC TeMPeraTure voluMe 

CoMPensaTIon (eTvC) KIT

In order to perform temperature compensation 

equations, the LectroCount LCR-II relies on a 

temperature probe inserted into the strainer housing. 

Installation directions for the ETVC kit are included in 

this manual. 

MeTer sysTeM overvIeW 

Содержание LectroCount LCR-II E3657 Series

Страница 1: ...LectroCount LCR II Installation Liquid Controls An IDEX Energy Fuels Business Operation EM150 21 E3657 E3658 Series LectroCount LCR II SELECT INCREASE Gallons S3...

Страница 2: ...se 2 ou une alimentation lectrique isol e et comportant un dispositif de protection contre la surtension de 5 amp res ou moins sont requises pour l installation Peripheral equipment must be suitable f...

Страница 3: ...a known good ground less than 1 Use a 12 ga or larger stranded wire Fixed Installations LectroCount housings directly mounted to the meter are attached to the earth ground through the meter via the ta...

Страница 4: ...ower cable Specifications Safety Tag Markings EU Explosive Atmospheres symbol This equipment has been found to comply with the European Directive for Equipment For Potentially Explosive Atmospheres 94...

Страница 5: ...8 Dimensions Side Front Top 15 9 94 5 19 LectroCount LCR II 13 7 5 8 04 10 5 70 Rear...

Страница 6: ...ghts Measures custody transfer product delivery and ticket generation Metrological data collection Presetting by volume Multiple production selection Security settings Air and vapor elimination with p...

Страница 7: ...y standard for many applications Multi layered tickets are available to provide a physical record for both customers and business records The Epson roll printer is ideal for recording multiple custody...

Страница 8: ...xidation from the ground strap contact point Lock washers should penetrate any paint to ensure a good electrical connection Ensure a Good Ground LectroCount Ground Strap Kit 82185 Install the LectroCo...

Страница 9: ...nd discharge line valve nozzle 8 Leave the discharge line valve nozzle open while working on the system 1 Close the belly valve of the supply tank 2 Close the valve on the vapor return line 3 Close th...

Страница 10: ...es Data and Power Cable The LCR II shipment typically includes a gray 40 power cable and a 40 black data cable prewired to terminal blocks on the LCR II CPU board On typical truck installations the ca...

Страница 11: ...Preset Valve Single Stage Electro Pnuematic Valve with V 7 Valve S1 Solenoid V 7 Valve Electro Pnuematic Actuator LectroCount LCR II Gallons A2859 11 Block Valve and 3 Way Solenoid Single Stage 3 Way...

Страница 12: ...eries Electro Pnuematic Valve Electro pnuematic valves use a S1 solenoid operated valve mounted to a pneumatic actuator to open and close a V 7 valve These valves are typically used in high viscosity...

Страница 13: ...llations When ordered as part of a meter system with a LCR II Liquid Control s optical air and vapor eliminators are bolted onto the strainer and wired to the LCR II at the factory Optical air and vap...

Страница 14: ...d PN 81944 that mounts directly to the LCR II CPU board Typically a P transducer operates in conjuction with a shutdown device such as a valve or a dead man The shutdown control must be wired to the L...

Страница 15: ...llation J1 RS 232 A Liquid Controls meter system with a LCR II typically includes an Epson slip printer or roll printer Installation is the same for both printers LCR II s are typically shipped with a...

Страница 16: ...ng Device B RS 485 J2 24 red J2 25 violet Multimeter Network B RS 485 J2 24 red J2 25 violet Power Installation Power Installation Overview When you have made all of the data connections and finished...

Страница 17: ...r the LCR II has been installed check to make sure that it powers up correctly The LCR II display and the printer power light should come on when the truck s ignition is turned to the ON or to the ACC...

Страница 18: ...er provided and held in place with the cotter pin provided The control switch on the front of the LCR II is also sealed with an O ring and held in place by a bushing secured with three socket head cap...

Страница 19: ...sher 2 81994 PULSER 100 PPR Pulser Field Install Kit 82597 08189 Flat Washer 08201 O ring 2 Optional Items not shown Description Part Number Roll Printer Extension Cable 71237 Flash Cable 81885 Lap Pa...

Страница 20: ......

Страница 21: ...2014 Liquid Controls Pub No 500392 7 14 105 Albrecht Drive Lake Bluff IL 60044 2242 1 800 458 5262 847 295 1050 Fax 847 295 1057 www lcmeter com...

Отзывы: