background image

32

33

PoWer InsTallaTIon 

Connect the Power

All LCR-II shipments typically include a 40' gray power cable (100', and 300' are also available) and a 5 A fuse. 

40’ Gray PoWer Cable 

The gray power cable (PN 84046) is prewired to the J6 terminal on the CPU board at the factory. It includes two 16 

AWG wires and a ground drain wire. The 5 A fuse should be spliced into the red 16 AWG wire as close to the power 

source as possible. 

ePson PrInTer PoWer

Power must be supplied to the Epson printer as well. A 15' cable with a 12/24 VDC converter (825001) for printer 

power supply is also available. The red wire of this cable must be spliced into the red wire of the gray power cable on 

the LCR-II side of the 5 A fuse.

1.  Route the gray power cable to the accessory panel. 

See 

page 17.

2.  Splice the red wire from the printer power cable into the 

red wire of the gray power cable.

3.   Splice the 5 A fuse into the red wire. Make the splice 

close to the direct power terminal connection in the 

accessory panel and on the power side of the splice 

made with the printer power cable.

Power Check

After the LCR-II has been installed, check to make sure that it powers up correctly. The LCR-II display and the printer 

power light should come on when the truck’s ignition is turned to the ON or to the ACC position. Make sure the printer 

power switch is on. If the LCR-II or the printer does not power up, check the wiring and the connections on the LCR-II 

CPU board against the manual. 

4.  Connect the red wire to the direct power supply terminal 

in the accessory panel.

5.  Connect the black wire of the gray power cable to a 

reliable DC ground.

6.  Connect the black wire of the printer power to a reliable 

DC  ground.

7.  Tape the green drain wire of the gray power cable back 

against the power cable.

To connect power to the lCr-II and the epson printer:

Page 17 describes describe the best practices for routing the gray power cable to the truck cab’s accessory panel. 

PoWer InsTallaTIon 

 Gray Power Cable 40’ 

(81512-UL) 
(81712-IECEx / INMETRO / ATEX)

EARTH/

Blue 

(13)

GND/

Black 

(12)

+12-24

/Red 

(11)

In-Line Fuse

Drain Wire

GROUND

Accessory Panel

Direct

Power

Supply

POWER  J6

DC

11

10

12

13

 Gray Power Cable

(see below)

Black Data Cable 

In-Line Fuse

Black

Red

Red

Accessory Panel

Chassis or Reliable Ground

DC Ground 

Power

Supply

epson Printer Power Connections

lectroCount lCr-II Power Connections

Содержание LectroCount LCR-II E3657 Series

Страница 1: ...LectroCount LCR II Installation Liquid Controls An IDEX Energy Fuels Business Operation EM150 21 E3657 E3658 Series LectroCount LCR II SELECT INCREASE Gallons S3...

Страница 2: ...se 2 ou une alimentation lectrique isol e et comportant un dispositif de protection contre la surtension de 5 amp res ou moins sont requises pour l installation Peripheral equipment must be suitable f...

Страница 3: ...a known good ground less than 1 Use a 12 ga or larger stranded wire Fixed Installations LectroCount housings directly mounted to the meter are attached to the earth ground through the meter via the ta...

Страница 4: ...ower cable Specifications Safety Tag Markings EU Explosive Atmospheres symbol This equipment has been found to comply with the European Directive for Equipment For Potentially Explosive Atmospheres 94...

Страница 5: ...8 Dimensions Side Front Top 15 9 94 5 19 LectroCount LCR II 13 7 5 8 04 10 5 70 Rear...

Страница 6: ...ghts Measures custody transfer product delivery and ticket generation Metrological data collection Presetting by volume Multiple production selection Security settings Air and vapor elimination with p...

Страница 7: ...y standard for many applications Multi layered tickets are available to provide a physical record for both customers and business records The Epson roll printer is ideal for recording multiple custody...

Страница 8: ...xidation from the ground strap contact point Lock washers should penetrate any paint to ensure a good electrical connection Ensure a Good Ground LectroCount Ground Strap Kit 82185 Install the LectroCo...

Страница 9: ...nd discharge line valve nozzle 8 Leave the discharge line valve nozzle open while working on the system 1 Close the belly valve of the supply tank 2 Close the valve on the vapor return line 3 Close th...

Страница 10: ...es Data and Power Cable The LCR II shipment typically includes a gray 40 power cable and a 40 black data cable prewired to terminal blocks on the LCR II CPU board On typical truck installations the ca...

Страница 11: ...Preset Valve Single Stage Electro Pnuematic Valve with V 7 Valve S1 Solenoid V 7 Valve Electro Pnuematic Actuator LectroCount LCR II Gallons A2859 11 Block Valve and 3 Way Solenoid Single Stage 3 Way...

Страница 12: ...eries Electro Pnuematic Valve Electro pnuematic valves use a S1 solenoid operated valve mounted to a pneumatic actuator to open and close a V 7 valve These valves are typically used in high viscosity...

Страница 13: ...llations When ordered as part of a meter system with a LCR II Liquid Control s optical air and vapor eliminators are bolted onto the strainer and wired to the LCR II at the factory Optical air and vap...

Страница 14: ...d PN 81944 that mounts directly to the LCR II CPU board Typically a P transducer operates in conjuction with a shutdown device such as a valve or a dead man The shutdown control must be wired to the L...

Страница 15: ...llation J1 RS 232 A Liquid Controls meter system with a LCR II typically includes an Epson slip printer or roll printer Installation is the same for both printers LCR II s are typically shipped with a...

Страница 16: ...ng Device B RS 485 J2 24 red J2 25 violet Multimeter Network B RS 485 J2 24 red J2 25 violet Power Installation Power Installation Overview When you have made all of the data connections and finished...

Страница 17: ...r the LCR II has been installed check to make sure that it powers up correctly The LCR II display and the printer power light should come on when the truck s ignition is turned to the ON or to the ACC...

Страница 18: ...er provided and held in place with the cotter pin provided The control switch on the front of the LCR II is also sealed with an O ring and held in place by a bushing secured with three socket head cap...

Страница 19: ...sher 2 81994 PULSER 100 PPR Pulser Field Install Kit 82597 08189 Flat Washer 08201 O ring 2 Optional Items not shown Description Part Number Roll Printer Extension Cable 71237 Flash Cable 81885 Lap Pa...

Страница 20: ......

Страница 21: ...2014 Liquid Controls Pub No 500392 7 14 105 Albrecht Drive Lake Bluff IL 60044 2242 1 800 458 5262 847 295 1050 Fax 847 295 1057 www lcmeter com...

Отзывы: