background image

12

13

MeTer sysTeM overvIeW 

Epson Slip Printer

Epson Roll Printer

Remote Display

POD Pulser

∆P Transducer

DMS

Lap Pad

Meter system Components

Pulse ouTPuT devICe

The Liquid Controls Pulse Output Device (POD pulser) 

converts the rotary motion of a positive displacement 

flowmeter into electronic pulses. POD pulsers can be 

used in place of an internal pulser. They are ideal for 

applications that require explosion proof components in 

which the LectroCount LCR-II register is installed at a 

distance from the meter. The POD pulser requires hard 

wired data communication with the LectroCount LCR-II. 

See manual EM300-11.

DifferenTiAl Pressure (∆P) TrAnsDuCer

The differential pressure transducer, common in 

aviation applications, monitors the differential pressure 

(pressure drop) across a full flow fuel monitor/water 

coalescer. The highest differential pressure reached 

during the custody transfer will then be printed on the 

ticket. Using interlocks, the LectroCount LCR-II can 

shut down a custody transfer if the differential pressure 

meets a preprogrammed differential pressure shutdown 

value. The ∆P Transducer requires hard wired data 

communication with the LectroCount LCR-II. See 

manual EM300-40.

daTa ManaGeMenT sysTeM

The DMS is an in-cab computer with a heavy duty lap 

pad interface. The DMS streamlines the flow of data 

between the LCR-II and back office accounting software. 

The DMS must be hard wired to the LectroCount LCR-II. 

See manuals EM200-10 and EM200-11.

laP Pad

The lap pad programs and displays all operational 

functions of the LectroCount LCR registers. It has a 

large, tactile, alpha-numeric keyboard and a dual line, 

backlit display.  A 3-terminal lap pad adapter is provided 

with each lap pad. The adapter provides a junction for 

the lap pad, the printer, and the LCR printer cable.   

xl led reMoTe dIsPlay

The XL LED Remote Display’s six 2¼” high digits, each 

consisting of 18 red LED lights, are discernible from up 

to 250 feet away. Hard wire data communication with the 

LectroCount LCR-II is required. See manual EM300-55.

PrInTers

Printers print delivery tickets to provide a physical record 

of custody transfers. The Epson slip printer is considered 

the industry standard for many applications. Multi-

layered tickets are available to provide a physical record 

for both customers and business records. The Epson roll 

printer is ideal for recording multiple custody transfers 

over an extended time frame. 

InsTallaTIon overvIeW

Installation overview

If the LectroCount LCR-II was ordered as part of a meter system, it will arrive mounted on the meter and prewired to 

the ETVC probe, air eliminator, and valve. 

Installation overview for lCr-II ordered with meter system:

1.  Ground truck seat cushion. 

page 12

2.  Install meter system onto truck or fixed installation. 

refer to meter manual

3.  Run the LCR-II’s data and power cable to truck cab or power supply. 

page 17

4.  Connect any additional components to the LCR-II’s CPU board.
5.  Mount printer and connect printer data cable. page 27
6.  Connect the LCR-II and the printer to power supply. page 29 
7.  Setup and calibrate the LCR-II. 

refer to manual EM150-11

If you are replacing an existing register, you must mount the register onto the meter and make the proper connections 

to all of the components.

Installation overview for lCr-II ordered without meter system:

1.  Ground truck seat cushion. 

page 12

2.  Mount the LCR-II to the meter. 

page 14

3.  Run the LCR-II’s data and power cable to truck cab or power supply. 

page 17

4.  Connect all components to the LCR-II’s CPU board.
5.  Mount printer and connect printer data cable. 

page 27

6.  Connect the LCR-II and the printer to power supply. 

page 29

 

7.  Setup and calibrate the LCR-II. 

refer to manual EM100-11

.

Before installation, check your shipment against the 

packing list and ensure that no parts are missing. The 

packing list is inside the red information packet along with 

the Installation and Operation Manuals.

Check Each Shipment

Specific installation requirements will vary with the model of the truck, the physical layout 

of a fixed installation, the configuration of any existing metering equipment, the options 

selected, and the type of fluid being metered

Installation Requirements Vary

This manual explains and details the mechanical installation of the 

LectroCount LCR-II and the temperature probe as well as the electrical and 

data installation of all components that connect to the LCR-II. For additional 

installation information, refer to the manuals of the other components. All 

manuals are available at www.lcmeter.com.

This Manual Includes 

Содержание LectroCount LCR-II E3657 Series

Страница 1: ...LectroCount LCR II Installation Liquid Controls An IDEX Energy Fuels Business Operation EM150 21 E3657 E3658 Series LectroCount LCR II SELECT INCREASE Gallons S3...

Страница 2: ...se 2 ou une alimentation lectrique isol e et comportant un dispositif de protection contre la surtension de 5 amp res ou moins sont requises pour l installation Peripheral equipment must be suitable f...

Страница 3: ...a known good ground less than 1 Use a 12 ga or larger stranded wire Fixed Installations LectroCount housings directly mounted to the meter are attached to the earth ground through the meter via the ta...

Страница 4: ...ower cable Specifications Safety Tag Markings EU Explosive Atmospheres symbol This equipment has been found to comply with the European Directive for Equipment For Potentially Explosive Atmospheres 94...

Страница 5: ...8 Dimensions Side Front Top 15 9 94 5 19 LectroCount LCR II 13 7 5 8 04 10 5 70 Rear...

Страница 6: ...ghts Measures custody transfer product delivery and ticket generation Metrological data collection Presetting by volume Multiple production selection Security settings Air and vapor elimination with p...

Страница 7: ...y standard for many applications Multi layered tickets are available to provide a physical record for both customers and business records The Epson roll printer is ideal for recording multiple custody...

Страница 8: ...xidation from the ground strap contact point Lock washers should penetrate any paint to ensure a good electrical connection Ensure a Good Ground LectroCount Ground Strap Kit 82185 Install the LectroCo...

Страница 9: ...nd discharge line valve nozzle 8 Leave the discharge line valve nozzle open while working on the system 1 Close the belly valve of the supply tank 2 Close the valve on the vapor return line 3 Close th...

Страница 10: ...es Data and Power Cable The LCR II shipment typically includes a gray 40 power cable and a 40 black data cable prewired to terminal blocks on the LCR II CPU board On typical truck installations the ca...

Страница 11: ...Preset Valve Single Stage Electro Pnuematic Valve with V 7 Valve S1 Solenoid V 7 Valve Electro Pnuematic Actuator LectroCount LCR II Gallons A2859 11 Block Valve and 3 Way Solenoid Single Stage 3 Way...

Страница 12: ...eries Electro Pnuematic Valve Electro pnuematic valves use a S1 solenoid operated valve mounted to a pneumatic actuator to open and close a V 7 valve These valves are typically used in high viscosity...

Страница 13: ...llations When ordered as part of a meter system with a LCR II Liquid Control s optical air and vapor eliminators are bolted onto the strainer and wired to the LCR II at the factory Optical air and vap...

Страница 14: ...d PN 81944 that mounts directly to the LCR II CPU board Typically a P transducer operates in conjuction with a shutdown device such as a valve or a dead man The shutdown control must be wired to the L...

Страница 15: ...llation J1 RS 232 A Liquid Controls meter system with a LCR II typically includes an Epson slip printer or roll printer Installation is the same for both printers LCR II s are typically shipped with a...

Страница 16: ...ng Device B RS 485 J2 24 red J2 25 violet Multimeter Network B RS 485 J2 24 red J2 25 violet Power Installation Power Installation Overview When you have made all of the data connections and finished...

Страница 17: ...r the LCR II has been installed check to make sure that it powers up correctly The LCR II display and the printer power light should come on when the truck s ignition is turned to the ON or to the ACC...

Страница 18: ...er provided and held in place with the cotter pin provided The control switch on the front of the LCR II is also sealed with an O ring and held in place by a bushing secured with three socket head cap...

Страница 19: ...sher 2 81994 PULSER 100 PPR Pulser Field Install Kit 82597 08189 Flat Washer 08201 O ring 2 Optional Items not shown Description Part Number Roll Printer Extension Cable 71237 Flash Cable 81885 Lap Pa...

Страница 20: ......

Страница 21: ...2014 Liquid Controls Pub No 500392 7 14 105 Albrecht Drive Lake Bluff IL 60044 2242 1 800 458 5262 847 295 1050 Fax 847 295 1057 www lcmeter com...

Отзывы: