9
User Guide
Grounding Your Machine
The 4x00 machines require an earth ground rod to ensure personnel safety, and to supress the high-frequency noise created by
the plasma power supply. A star ground point on the table will connect directly to the earth ground rod via a 6 AWG stranded
wire or other stranded, grounding cable. Consult with a qualified electrician to verify your connections.
Step 1:
Place the plasma unit into the
appropriate location.
Re-install the power lead and
the table ground into the front
of the machine.
Step 2:
The FlexCut plasma unit is
shipped with a factory ground
attached to the star ground.
In addition, a work ground is
attached to the star ground to
connect to your material to be
cut.
If the work piece is painted or
dirty, it may be necessary to
expose the bare metal to make
a good electrical connection.
Please Note:
• Use 6 AWG stranded wire to connect the star ground on the table to the customer supplied dedicated earth
ground.
• For proper operation of your CNC cutting tables you are required to run a 6 AWG cable from the “star”
ground to a dedicated earth-ground rod.
• Ground rod installations are covered by NEC Section 250.
• The earth ground is not included with the machine.