Basic Troubleshooting
Machine Faults:
Laser Faults:
Problem
Solution
One motor will not engage when DATUM the
machine.
LOG ON as ADMIN. Reload your configuration. Press OK.
DATUM machine.
If the issue still persists, contact Customer Support.
Binding of the gantry when running parts
Grease the side cassettes. If the issue still persists, contact
Customer Support.
Cuts are not coming out square or degraded cut
quality
Check consumables in the Plasma torch along with the
settings from the cut chart.
Check the torch is square to the material on the table.
Follow the CUT QUALITY section pg. 29
Problem
Solution
An error message occurs when attempting to
turn the Laser on stating "The laser cannot be
activated in Active Run"
Toggle the system to Dry Run mode.
The laser does not appear to be landing where
the centerline of the torch would be on the
material
Reset the Z axis. If a larger error is reported, the laser po-
sition would be off. Enter the material thickness decimal
equivalant, and turn the laser off and back on again.