Software Faults (Cont.):
Problem
Solution
Torch retracts fully to the top after sensing the
material in an ohmic sense, and the Run Job button
becomes available to click.
Clear the surface of the material of any corrosion that
would hinder the ohmic sensing process.
Verify the torch lead is not getting pulled tight on the
way down to the surface of the material.
Check for the torch pushing against the material
deflecting it before stopping and retracting.
Torch collides with the material after 1” of cut.
The torch is cutting too high from the material.
Verify Pierce and Cut height are at recommended
book values.
Verify the height control mode is set to Auto and not
Manual.
Verify the Sample Voltage function is turned ON.
Check for part tip-ups near the piercing points that
may interfere with the torch sensing the materials
height.
Torch does not appear to maintain a consistent cut
height with the material as it warps.
Verify the height control mode is set to Auto and not
Manual.
Verify the Sample Voltage function is turned ON.
If the part involves very complex geometry, the sys-
tem may be in a Lockout Mode for extended periods
of time.
Login as Admin, go to Machine Settings, and on the
Basic tab change the Distance to Corner value to .250.