SFA-5000 • SFA-10000 DeviceNet
Never release the wire freely, always help the wire wind properly: risk of
personal injury and/or equipment damage.
Always keep the wire aligned not to damage the equipment (maximum
deviation: 3°).
3.3 Useful information
If you want to know the
maximum measuring length
and the
physical linear
resolution
of the draw-wire encoder please refer to the order code. The stroke
per turn is always 200 mm (7.874”), the maximum number of turns is 25 for
SFA-5000 and 50 for SFA-10000.
EXAMPLE 1
SFA-
5000
-
FD
-
8192
-PG using the physical resolution (
= 00)
Stroke per turn of the drum = 200 mm (7.874”)
23-01-2A Hardware counts per revolution
, physical resolution per turn = 13
bits = 8,192 cpr
23-01-2B Hardware number of turns
, number of physical revolutions = 12
bits = 4,096 revolutions
Total physical resolution = 25 bits = 33,554,432 information
Physical linear resolution = 0.024 mm = 24 µm
Max. number of turns of the drum = 25
Max. measuring length = 5,000 mm (196.85”)
MAN SFA_5000_10000_FD E 1.0.odt