SFA-5000 • SFA-10000 DeviceNet
3.2 Mounting instructions
•
Fasten the draw-wire unit onto a fixed support using three M4 screws
1
;
•
remove the safety wire that pins the end of the measuring wire during
transport;
•
fix the end of the measuring wire to the moving unit using the provided
M6 nuts
2
.
WARNING
We suggest installing the unit providing protection means against waste,
especially swarf as turnings, chips, or filings; should this not be possible, please
make sure that adequate cleaning measures are in place in order to prevent the
wire from jamming.
To avoid irreparable failures, never exceed the maximum measuring length and
prevent the wire from tangling up.
MAN SFA_5000_10000_FD E 1.0.odt
Mounting instructions
15 of 88