SFA-5000 • SFA-10000 DeviceNet
6.5.3 Class 05h: Connection Object
The Connection Class allocates and manages the internal resources associated to
both “I/O Messages” and “Explicit Messaging Connections”.
Supported
Service code:
0Eh = Get_Attribute_Single: used to read connection class attribute value.
10h = Set_Attribute_Single: used to write connection class attribute value.
Supported
Instance:
01h = Explicit Message
02h =
04h =
(COS) /
05-Inst-01 Connection status
[USINT, ro]
This attribute defines the current status of the Connection instance. Value = 03
means that the connection has been configured correctly.
05-Inst-02 Instance type
[USINT, ro]
00h: Explicit messaging
01h: I/O messaging
05-Inst-03 TransportClass_trigger
[BYTE, ro]
It defines whether this is a producing only, consuming only, or both producing
and consuming connection.
05-Inst-04 Produced connection ID
[UINT, ro]
This is the value that will be specified in the CAN Identifier Field when this
Connection transmits.
05-Inst-05 Consumed connection ID
[UINT, ro]
This is the CAN Identifier Field value that is associated to the messages this
Connection Object receives.
05-Inst-06 Initial comm. Characteristics
[USINT, ro]
Defines the Message Group(s) the sent and received messages are related to.
Default = 21h
MAN SFA_5000_10000_FD E 1.0.odt
DeviceNet interface
63 of 88
Содержание SFA-10000-FD
Страница 85: ...This page intentionally left blank ...
Страница 86: ...This page intentionally left blank ...
Страница 87: ...This page intentionally left blank ...