SFA-5000 • SFA-10000 DeviceNet
Number of information = 204,800
EXAMPLE 2
SFA-
10000
-
FD
-
8192
-M12 using a custom resolution (
= 01)
Stroke per turn of the drum = 200 mm (7.874”)
23-01-2A Hardware counts per revolution
, physical resolution per turn = 13
bits = 8,192 cpr
23-01-2B Hardware number of turns
, number of physical revolutions = 12
bits = 4,096 revolutions
Custom resolution per turn =
23-01-10 Resolution per revolution
cpr (example)
23-01-11 Total measuring range
= 8,192,000 information (example)
Custom number of encoder revolutions =
23-01-11 Total measuring range
= 4,096
23-01-10 Resolution per revolution
Linear resolution = 0.1 mm = 100 µm
Max. number of turns of the drum = 50
Max. measuring length = 10,000 mm (393.7”)
Number of information = 100,000
3.4 Maintenance
The measuring system does not need any particular maintenance; anyway it has
to be handled with the utmost care as any delicate electronic equipment. From
time to time we recommend the following operations:
•
the unit and the wire have to be cleaned regularly using a soft and clean
cloth to remove dust, chips, moisture etc.; do not use oil to clean the
wire.
MAN SFA_5000_10000_FD E 1.0.odt
Mounting instructions
17 of 88
Содержание SFA-10000-FD
Страница 85: ...This page intentionally left blank ...
Страница 86: ...This page intentionally left blank ...
Страница 87: ...This page intentionally left blank ...