SFA-5000 • SFA-10000 DeviceNet
4.7 Setting the node address: DIP B
WARNING
Power supply must be turned off before performing this operation!
The node number must be set via hardware using DIP B dip-switches.
Allowed addresses range between 0 and 63.
The default address is 1.
Set the node address in binary value: ON=1, OFF=0
bit
1
LSB
2
3
4
5
6
MSB
7
not
used
8
not
used
2
0
2
1
2
2
2
3
2
4
2
5
EXAMPLE
Set the node address = 25:
25
10
= 0001 1001
2
(binary value)
bit
1
2
3
4
5
6
7
8
2
0
2
1
2
2
2
3
2
4
2
5
ON
OFF
OFF
ON
ON
OFF
OFF
OFF
Set the node address = 55:
55
10
= 0011 0111
2
(binary value)
bit
1
2
3
4
5
6
7
8
2
0
2
1
2
2
2
3
2
4
2
5
ON
ON
ON
OFF
ON
ON
OFF
OFF
MAN SFA_5000_10000_FD E 1.0.odt
Electrical connections
24 of 88
Содержание SFA-10000-FD