SFA-5000 • SFA-10000 DeviceNet
23-01-10 Resolution per revolution
) to calculate the position information.
This attribute is intended to show the number of physical distinguishable steps
per each revolution provided by the hardware (physical singleturn resolution).
If you want to set a custom singleturn resolution see the
23-01-2B Hardware number of turns
[UINT, ro]
WARNING
This attribute is active only if the
23-01-0E Scaling function control
is set to ”=00”; otherwise it is ignored and the system uses the custom values
(
23-01-10 Resolution per revolution
) to calculate the position information.
This attribute is intended to show the number of physical revolutions provided
by the hardware (number of physical revolutions).
The
Total hardware resolution
23-01-2B Hardware number of turns
If you want to set a custom number of revolutions see the
23-01-11 Total measuring range
on page 69 ff.
23-01-2C Alarms
[WORD, ro]
An alarm is set when a bit indicating a fault is set to true (high). See the
following
values.
23-01-2D Supported alarms
[WORD, ro]
This attribute contains information on the supported alarms.
Bits 0 … 11 Reserved
Bit 12
Flash memory error
Internal error, the alarm cannot be
restored.
Bit 13
Machine data not
valid
One or more parameters are not valid, set
proper values to restore normal work
condition.
Bit 14
Bus off
This bit is intended to warn that the
communication in the bus network has
MAN SFA_5000_10000_FD E 1.0.odt
DeviceNet interface
76 of 88