SFA-5000 • SFA-10000 CANopen®
4.3 Connection cap with M12 connectors
Connector output versions (...-M12 order code) are fitted with two M12
connectors with pin-out in compliance with the CANopen® standard. Therefore
you can use standard CAN cordsets and patchcords commercially available. For a
complete list of the available cordsets and patchcords please refer to the
product datasheet (“Accessories” list).
M12 5-pin connector
A coding
(frontal side)
male
(BUS IN)
female
(BUS OUT)
M12
Description
Case
CAN Shield
1
1
2
+10Vdc +30Vdc power supply
voltage
3
0Vdc power supply voltage
4
CAN High
5
CAN Low
1
CAN Shield is also connected to pin 1 to allow the connection
of the shield even if the plug connector has a plastic case.