SFA-5000 • SFA-10000 CANopen®
7 - Setting-up
Here following are some examples of transmission between Master and Slave
devices.
A generic “ID” value is used to indicate the encoder address; the Master address
is always 0. All values are expressed in hexadecimal notation.
7.1 Setting the
Operational
,
Pre-operational
state
NMT message
Master
Slave
COB-ID
Cmd
Node
Operational
:
000
01
ID
Pre-operational
:
000
80
ID
7.2 Setting the resolution per revolution
6001-00 Measuring units per revolution
(2
13
=0000 2000h)
Master
Encoder (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
23
01
60
00
00
20
0
00
Encoder
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
01
60
00
00
00
00
00
7.3 Setting the total resolution
(2
25
=0200 0000h)
Master
Encoder (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
23
02
60
00
00
00
00
02
Encoder
Master (Set confirmation)
COB-ID
Cmd
Index
Sub
Process data
580+ID
60
02
60
00
00
00
00
00
7.4 Setting the Operating parameters
: 1 = count up information pulling the wire out,
: 1 = enabled,
: 0 = disabled)
Master
Encoder (Set request)
COB-ID
Cmd
Index
Sub
Process data
600+ID
2B
00
60
00
05
00
-
-
MAN SFA_5000_10000_CB E 1.0.odt
7 - Setting-up
79 of 88
Содержание CANopen SFA-10000-CB
Страница 85: ...This page intentionally left blank...
Страница 86: ...This page intentionally left blank...
Страница 87: ...This page intentionally left blank...