Error 162
Error Message Displayed to user
E162
Condition
SPI Watchdog Timeout
Cause
• Board failed to read from IO board within threshold.
• Reseat flat flex cables
• Replace flat flex cables
• Replace Message Center PCBA
• Replace console
Remedy
• Unplug flat flex cable (FFC) at MSG CTR connector (J13 on Main PCBA), then re-insert FFC into MSG CTR
Connector (J13 on Main PCBA) and latch connector.
• If still fails, then repeat with the other end of the FFC at J1 on Message Center PCBA.
• If still fails, replace FFC cable.
• If still fails, replace Message Center PCBA.
• If still fails, replace console.