Error 82
Error Message Displayed to user
•
E82
•
Notify Maintenance!
Dump Resistor Error
Keep error on screen until
OK
button pressed.
Condition
Error sent by MC when the dump resistor maximum 'on-time' has been exceeded. Thus maximum allowed resistor
power was dissipated for an excessive period.
Cause
• Excessive user weight at high speed
• Damaged bus dump resistor
• Wrong power resistor value
Remedy
• Check condition of dump resistor and resistor wiring. Repair / replace as needed.
• Check / measure value of dump resistor (100 Ohm). Replace as needed.
• Is error repeatable? Diagnose / replace MDB.
• If not repeatable error could have been caused by heavy / highspeed / extreme workout or temporary high input
voltage.