Error 94
Error Message Displayed to user
•
E94
•
Notify Maintenance No Motor Current
Keep error on screen until
OK
button pressed.
Condition
No Motor Current measured
Cause
• Motor might be unplugged from Motor Controller board
• Bad Motor Controller
Remedy
• Check to verify motor is plugged into Motor Drive Board / Motor Controller board.
• Check motor and motor cabling for damage. Repair / replace as needed.
• Check motor phase continuity
• Replace Motor Drive Board / Motor Controller
Page 115 of 153