Error 98
Error Message Displayed to user
•
E98
•
Boot Checksum
Condition
This message is shown at power-up if the boot update software has failed a checksum integrity check, where
xxxxx
will be a number.
Cause
• Bad main PCBA
• Bad Motor controller / SIB / RCB PCBA
• Bad Motor Drive Board
Remedy
• If Console, reprogram main PCBA. If error continues, replace main PCBA. If error still continues, then replace
console.
• If Base, reprogram Motor controller / SIB / RCB PCBA. If error continues, replace Motor controller / SIB / RCB PCBA.
Replace Motor Drive Board / Motor Controller.