Estimating RF Coverage
6-16
InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620003-0-20 Rev J
Table 6-15
Approximate Radiated Distance from Antenna
for 800 MHz iDEN Applications
Facility
Distance from Antenna
Meters
Feet
Open Environment
75
244
Moderately Open Environment
64
208
Mildly Dense Environment
56
184
Moderately Dense Environment
48
156
Dense Environment
40
131
Table 6-16
Approximate Radiated Distance from Antenna
for 900 MHz GSM Applications
Facility
Distance from Antenna
Meters
Feet
Open Environment
70
230
Moderately Open Environment
60
197
Mildly Dense Environment
53
174
Moderately Dense Environment
45
148
Dense Environment
38
125
Table 6-17
Approximate Radiated Distance from Antenna
for 900 MHz EGSM Applications
Facility
Distance from Antenna
Meters
Feet
Open Environment
70
231
Moderately Open Environment
60
197
Mildly Dense Environment
53
174
Moderately Dense Environment
45
149
Dense Environment
38
125