Help Hot Line (U.S. only): 1-800-530-9960
6-5
D-620003-0-20 Rev J
CONFIDENTIAL
Maximum Output Power Per Carrier at RAU
6.1.2
800 MHz iDEN/SMR
Table 6-2
iDEN/SMR Power per Carrier
No. of
Carriers
Power per Carrier (dBm)
iDEN
2 km SMF/
1 km MMF
Analog FM
2 km SMF/
1 km MMF
CQPSK
2 km SMF/
1 km MMF
C4FM
2 km SMF/
1 km MMF
Motient Data
TAC
2 km SMF/
1 km MMF
1
10.0
10.0
10.0
10.0
10.0
2
10.0
10.0
10.0
10.0
10.0
3
10.0
10.0
10.0
10.0
10.0
4
10.0
10.0
10.0
10.0
10.0
5
9.0
10.0
10.0
10.0
6
8.0
10.0
9.5
10.0
7
7.0
9.5
9.0
9.0
8
6.5
8.5
8.0
8.5
9
6.0
8.0
7.5
7.5
10
5.5
7.0
7.0
7.0
Note: Operation at or above these output power levels may prevent Unison from meeting RF performance specifications or FCC Part 15 and EN55022 emis-