Expansion Hub Specifications
4-8
InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620003-0-20 Rev J
4.4
Expansion Hub Specifications
Table 4-4
Expansion Hub Specifications
Specification
Description
Enclosure Dimensions (H
×
W
×
D)
89 mm × 438 mm × 305 mm (3.5 in. × 17.25 in. × 12 in.)
2U
Weight
< 5 kg (< 11 lb)
Operating Temperature
c
0° to +45°C (+32° to +113°F)
Non-operating Temperature
c
–20° to +85°C (–4° to +185°F)
Operating Humidity, non-condensing
5% to 95%
Cat-
5/5E/6
Connectors
a
a.
It is important that you use only Cat-5/5E/6 ScTP cable with shielded RJ-45 connectors.
8 shielded RJ-45, female (Cat-5/6)
Fiber Connectors
b
b. It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including
fiber distribution panels.
c. For Japan, see separate addendum -
Japan Specification Document
.
1 Pair, SC/APC
LED Alarm and Status Indicators
Unit Status (1 pair):
• Power
• E-Hub Status
Fiber Link Status (1 pair):
• DL Status
• UL Status
RAU/Link Status (1 pair per RJ-45 port):
• Link
• RAU
AC Power (Volts) (47–63 Hz)
Rating: 115/230V, 5/2.5A, 50–60 Hz
Operating Range: 90–132V/170–250V auto-ranging,
2.2–1.5A/1.2–0.8A, 47–63 Hz
Power Consumption (W)
4 RAUs: 120 typical/148 max
4 RAUs & 4 Extenders: 137 typical/172 max
8 RAUs: 170 typical/212 max
8 RAUs & 8 Extenders: 204 typical/260 max
MTBF