System Specifications
2-14
InterReach Unison Installation, Operation, and Reference Manual
CONFIDENTIAL
D-620003-0-20 Rev J
2.5.1
InterReach Unison Wavelength and Laser Power
Table 2-4 shows wavelength and laser power according to UL testing per IEC 60
825-1.
Table 2-4
InterReach Unison Wavelength and Laser Power
2.5.2
Environmental Specifications
Table 2-5
Environmental Specifications
*It is critical to system performance that only SC/APC fiber connectors are used throughout the fiber network, including fiber distribution panels.
** For Japan, see separate addendum
–
Japan Specification Document
.
†Excluding angle-brackets for 19'' rack mounting of hubs.
Note: Expansion Hub typical power consumption assumes that the Cat-5/6 cable length is no more than 100 meters without a Cat-5 Extender and
no more than 170 meters with a Cat-5 Extender.
Wavelength
Measured Output Power
Main Hub
Expansion Hub
1310 nm ±20 nm
458 uW
1.8 mW
Parameter
Main Hub and Expansion Hub
RAU
Operating Temperature
0° to +45°C (+32° to +113°F)
–25° to +45°C (–13° to +113°F)
Non-operating Temperature
–20° to +85°C (–4° to +185°F)
–25° to +85°C (–13° to +185°F)
Operating Humidity; non-condensing
5% to 95%
5% to 95%