Hydro Kit DIP Switch Settings
PRE-COMMISSIONING
Hydro Kit DIP Switch Settings
The Hydro Kit can be used for various applications, therefore, it is
important to set up the system and the DIP switches properly. See
tables below for DIP switch settings to functions.
• Always turn off electric power before setting the DIP switches.
There is a risk of electric shock, physical injury, and / or death.
•
Do not operate the Hydro Kit unit in Antifreeze Operation Mode
until after the proper amount of antifreeze is added to the water
circuit. The product will freeze and burst, causing physical injury
and / or death.
•
Do not add any antifreeze during Hot Water Mode operation.
• If the Hydro Kit is not configured precisely, it will operate improperly
or the performance will be degraded.
• When the DIP switch is in the UP position, it is ON; when the DIP
switch is in the DOWN position, it is OFF.
Table 31: Hydro Kit DIP Switch Group 2 Settings and Descriptions.
Figure 102: Hydro Kit DIP Switch PCB Locations.
Description
DIP Switch Group 2 Settings
Function
Default
1
2
3
4
5
6
7
8
Group Control
X
Master
¥
Ɣ
Slave
Installation
Application
X
X
Floor Heating Only
Ɣ
X
Water Tank (Domestic Hot Water) + Floor H Solar Panel
X
Ɣ
Water Tank (Domestic Hot Water) + Floor Heating
¥
Ɣ
Ɣ
Water Tank (Domestic Hot Water) Only
Operation Mode
Setting
X
Heating Only
¥
Ɣ
Heating / Cooling
Flow Switch
Detection
X
Always
Ɣ
While Water Pump is On
¥
Electric Heater
Setup
X
X
Not Use
¥
X
Ɣ
Reserved (
Don’t Select)
Ɣ
X
Ɣ
Ɣ
Thermostat
Connection
X
Thermostat NOT Installed
¥
Ɣ
Thermostat Installed
Ɣ 2Q
; 2II
OFF
DIP
Switch
Group 1
N/A--
Not for Use
ON
1 2 3 4
OFF
ON
2
1 3
4
OFF is selected
ON is selected
OFF
ON
DIP Switch
Group 2
1 2 3
5 6 7 8
4
DIP Switch
Group 3
13
24
2
13
4
12
3
4
56
7
8